Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
596
matching recommendationsSIC | 3325 | Steel Foundries, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0525 # 05 Y:1997 | 05 | 1997 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,850 | $4,477 | Not Implemented |
OK0525 # 06 Y:1997 | 06 | 1997 | IMPROVE COMBUSTION CONTROL CAPABILITY | $1,033 | $2,805 | Not Implemented |
OK0525 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $147 | $278 | Not Implemented |
OK0525 # 08 Y:1997 | 08 | 1997 | INSTALL OCCUPANCY SENSORS | $134 | $116 | Implemented |
OK0525 # 09 Y:1997 | 09 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $28,080 | $2,090 | Not Implemented |
OK0525 # 01 Y:1997 | 01 | 1997 | RECYCLE CASTING SAND | $290,422 | $282,500 | Not Implemented |
OK0525 # 02 Y:1997 | 02 | 1997 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $9,080 | $1,260 | Not Implemented |
KG0089 # 01 Y:1997 | 01 | 1997 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $39,149 | $0 | n/a |
KG0089 # 02 Y:1997 | 02 | 1997 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $6,852 | $790 | n/a |
KG0089 # 03 Y:1997 | 03 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,955 | $3,380 | n/a |
KG0089 # 04 Y:1997 | 04 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $4,400 | $0 | n/a |
KG0089 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,294 | $422 | n/a |
KG0089 # 06 Y:1997 | 06 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $1,006 | $600 | n/a |
KG0089 # 07 Y:1997 | 07 | 1997 | SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED | $4,062 | $7,900 | n/a |
KG0089 # 08 Y:1997 | 08 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $550 | $300 | n/a |
KG0089 # 09 Y:1997 | 09 | 1997 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $258 | $0 | n/a |
KG0089 # 10 Y:1997 | 10 | 1997 | MOVE PRODUCT USING MECHANICAL MEANS | $27,325 | $1,612 | n/a |
MS0082 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $356 | $1,798 | Not Implemented |
MS0082 # 02 Y:1997 | 02 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,263 | $7,718 | Not Implemented |
MS0082 # 03 Y:1997 | 03 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $43,945 | $22,016 | Not Implemented |
MS0082 # 04 Y:1997 | 04 | 1997 | USE SAND FOR OTHER PURPOSES (EG CONSTRUCTION FILL, COVER FOR MUNICIPAL LANDFILLS) | $46,250 | $0 | Implemented |
MS0082 # 05 Y:1997 | 05 | 1997 | SELL OIL TO RECYCLER | $205 | $0 | Not Implemented |
MS0082 # 06 Y:1997 | 06 | 1997 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $33,600 | $153,600 | Not Implemented |
AM0253 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $35,300 | $92,500 | Implemented |
AM0253 # 02 Y:1995 | 02 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,500 | $3,000 | Implemented |