Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

589

matching recommendations
Reset
SIC 3325 Steel Foundries, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0034 # 03 Y:2009 03 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,614 $14,475 Not Implemented
UA0034 # 04 Y:2009 04 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,360 $27,038 Not Implemented
UA0034 # 05 Y:2009 05 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,507 $1,344 Not Implemented
UA0034 # 06 Y:2009 06 2009 USE PHOTOCELL CONTROLS $1,372 $1,225 Not Implemented
UA0034 # 07 Y:2009 07 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $269 $2,100 Not Implemented
UA0034 # 08 Y:2009 08 2009 INSTALL TIMERS AND/OR THERMOSTATS $888 $680 Not Implemented
UA0034 # 09 Y:2009 09 2009 RECOVER WASTE HEAT FROM EQUIPMENT $1,640 $2,900 Not Implemented
UA0034 # 10 Y:2009 10 2009 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $3,885 $17,000 Not Implemented
UA0027 # 01 Y:2008 01 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,165 $1,644 Implemented
UA0027 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $252 $2,679 Not Implemented
UA0027 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,774 $14,051 Not Implemented
UA0027 # 04 Y:2008 04 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $682 $402 Not Implemented
UA0027 # 05 Y:2008 05 2008 INSULATE BARE EQUIPMENT $9,325 $55 Not Implemented
UA0027 # 06 Y:2008 06 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $23,489 $13,600 Not Implemented
UM0330 # 01 Y:2007 01 2007 RECOVER WASTE HEAT FROM EQUIPMENT $17,750 $12,000 Not Implemented
UM0330 # 02 Y:2007 02 2007 RECOVER WASTE HEAT FROM EQUIPMENT $4,366 $5,250 Not Implemented
UM0330 # 03 Y:2007 03 2007 REDUCE VENTILATION AIR $1,775 $516 Not Implemented
UM0330 # 04 Y:2007 04 2007 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,732 $1,300 Not Implemented
UM0330 # 05 Y:2007 05 2007 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,605 $500 Not Implemented
UM0330 # 06 Y:2007 06 2007 RECOVER WASTE HEAT FROM EQUIPMENT $1,228 $4,500 Not Implemented
UM0330 # 07 Y:2007 07 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $954 $1,500 Not Implemented
UM0330 # 08 Y:2007 08 2007 COVER OPEN TANKS $733 $1,000 Not Implemented
UD0749 # 01 Y:2006 01 2006 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $973,467 $1,500,000 Not Implemented
UD0749 # 02 Y:2006 02 2006 REDUCE VENTILATION AIR $359,088 $0 Not Implemented
UD0749 # 03 Y:2006 03 2006 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $211,000 $7,200 Implemented