Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsSIC | 333 | Primary Nonferrous Metals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0077 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $317 | $110 | Not Implemented |
MZ0077 # 01 Y:2011 | 01 | 2011 | INSTALL OCCUPANCY SENSORS | $6,493 | $1,100 | Not Implemented |
MZ0077 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $253 | $110 | Not Implemented |
MZ0077 # 04 Y:2011 | 04 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,103 | $2,400 | Not Implemented |
MZ0077 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,655 | $800 | Not Implemented |
MZ0077 # 06 Y:2011 | 06 | 2011 | IMPROVE COMBUSTION CONTROL CAPABILITY | $38,690 | $0 | Not Implemented |
MZ0077 # 07 Y:2011 | 07 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,741 | $28,000 | Not Implemented |
MZ0071 # 06 Y:2011 | 06 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,545 | $1,133 | Not Implemented |
MZ0071 # 09 Y:2011 | 09 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,831 | $0 | Implemented |
MZ0071 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,810 | $1,300 | Implemented |
MZ0071 # 04 Y:2011 | 04 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $19,137 | $1,000 | Implemented |
MZ0071 # 03 Y:2011 | 03 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $429 | $0 | Implemented |
MZ0071 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $285 | $610 | Implemented |
MZ0071 # 01 Y:2011 | 01 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $15,644 | $3,400 | Not Implemented |
MZ0071 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,223 | $800 | Implemented |
MZ0071 # 08 Y:2011 | 08 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $35 | $50 | Implemented |
MZ0071 # 10 Y:2011 | 10 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,736 | $6,494 | Implemented |
MZ0070 # 02 Y:2011 | 02 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,693 | $920 | Implemented |
MZ0070 # 03 Y:2011 | 03 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,071 | $1,122 | Implemented |
MZ0070 # 04 Y:2011 | 04 | 2011 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,769 | $360 | Implemented |
MZ0070 # 05 Y:2011 | 05 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $40,140 | $10,000 | Implemented |
MZ0070 # 06 Y:2011 | 06 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $209 | $200 | Not Implemented |
MZ0070 # 07 Y:2011 | 07 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $21,157 | $16,730 | Not Implemented |
MZ0070 # 01 Y:2011 | 01 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,076 | $800 | Implemented |
MZ0044 # 07 Y:2009 | 07 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,155 | $10,000 | Not Implemented |