Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

469

matching recommendations
Reset
SIC 334 Secondary Nonferrous Metals
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0253 # 07 Y:2002 07 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,476 $120 Implemented
WV0253 # 08 Y:2002 08 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $8,080 $1,755 Not Implemented
WV0253 # 09 Y:2002 09 2002 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $122 $40 Implemented
WV0253 # 10 Y:2002 10 2002 $4,800 $1,000 Implemented
UU0027 # 01 Y:2002 01 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,326 $9,484 Not Implemented
UU0027 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,774 $180 Implemented
UU0027 # 03 Y:2002 03 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $631 $442 Not Implemented
UU0027 # 04 Y:2002 04 2002 OPTIMIZE PLANT POWER FACTOR $6,600 $4,500 Implemented
UU0027 # 05 Y:2002 05 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $13,770 $12,000 Not Implemented
MA0511 # 01 Y:2002 01 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $38,495 $4,090 Implemented
MA0511 # 02 Y:2002 02 2002 $15,314 $0 Implemented
MA0511 # 03 Y:2002 03 2002 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $10,764 $14,100 Implemented
MA0511 # 04 Y:2002 04 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,282 $6,950 Implemented
MA0511 # 05 Y:2002 05 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $605 $0 Implemented
MA0511 # 06 Y:2002 06 2002 $483 $0 Implemented
MA0511 # 07 Y:2002 07 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $249 $0 Implemented
MA0511 # 08 Y:2002 08 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $86 $350 Implemented
SF0218 # 01 Y:2001 01 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $3,760 $0 Not Implemented
SF0218 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,973 $360 Implemented
SF0218 # 03 Y:2001 03 2001 MODERATE COOLING TOWER OUTLET TEMPERATURE $1,846 $495 Not Implemented
SF0218 # 04 Y:2001 04 2001 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $670 $420 Not Implemented
SF0218 # 05 Y:2001 05 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $2,703 $2,200 Not Implemented
SF0218 # 06 Y:2001 06 2001 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $4,406 $4,080 Implemented
SF0218 # 07 Y:2001 07 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,754 $11,785 Implemented
SF0218 # 08 Y:2001 08 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,572 $6,779 Not Implemented