IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

28

matching recommendations
Reset
SIC 334 Secondary Nonferrous Metals
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0219 # 01 Y:1994 01 1994 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,622 $0 Implemented
WI0219 # 03 Y:1994 03 1994 INSTALL OCCUPANCY SENSORS $744 $375 Not Implemented
WI0219 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $644 $782 Implemented
UM0011 # 07 Y:1994 07 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,836 $5,735 n/a
UM0011 # 06 Y:1994 06 1994 COVER OPEN TANKS $3,577 $4,000 n/a
UM0011 # 05 Y:1994 05 1994 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $612 $3,100 n/a
UM0011 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $163 $0 n/a
UM0011 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $949 $350 n/a
UM0011 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,992 $4,523 n/a
UM0011 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,640 $2,810 n/a
UM0006 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,490 $4,330 Implemented
UM0006 # 05 Y:1994 05 1994 COVER OPEN TANKS $1,419 $1,123 Not Implemented
UM0006 # 04 Y:1994 04 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,799 $3,089 Implemented
UM0006 # 03 Y:1994 03 1994 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,710 $3,100 Implemented
UM0006 # 02 Y:1994 02 1994 USE PHOTOCELL CONTROLS $3,229 $5,400 Implemented
UM0004 # 05 Y:1994 05 1994 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $14,700 $3,560 Not Implemented
UM0004 # 04 Y:1994 04 1994 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $82,470 $39,200 Not Implemented
UM0004 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,138 $7,537 Not Implemented
UM0004 # 02 Y:1994 02 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $282 $500 Implemented
UM0004 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,971 $3,260 Implemented
AM0200 # 01 Y:1994 01 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $17,100 $17,000 Not Implemented
AM0200 # 06 Y:1994 06 1994 USE SYNTHETIC LUBRICANT $480 $0 Not Implemented
AM0200 # 05 Y:1994 05 1994 MINIMIZE WATER USAGE $1,250 $100 Implemented
AM0200 # 04 Y:1994 04 1994 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $1,380 $710 Not Implemented
AM0200 # 03 Y:1994 03 1994 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $3,950 $2,550 Not Implemented