Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
53
matching recommendationsSIC | 3341 | Secondary Nonferrous Metals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0888 # 05 Y:2013 | 05 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,528 | $0 | Not Implemented |
UD0888 # 06 Y:2013 | 06 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $74,025 | $55,000 | Not Implemented |
UD0888 # 07 Y:2013 | 07 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,011 | $0 | Implemented |
UD0888 # 08 Y:2013 | 08 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,313 | $0 | Implemented |
UD0888 # 09 Y:2013 | 09 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,246 | $3,000 | Implemented |
UD0888 # 10 Y:2013 | 10 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $695 | $0 | Not Implemented |
UD0888 # 11 Y:2013 | 11 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,284 | $15,000 | Implemented |
UD0888 # 13 Y:2013 | 13 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $10,444 | $4,500 | Not Implemented |
UD0888 # 14 Y:2013 | 14 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $3,770 | $0 | Implemented |
UD0888 # 15 Y:2013 | 15 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $913 | $2,119 | Not Implemented |
UD0888 # 16 Y:2013 | 16 | 2013 | INSULATE BARE EQUIPMENT | $6,807 | $894 | Not Implemented |
UD0888 # 17 Y:2013 | 17 | 2013 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,679 | $5,000 | Not Implemented |
UD0888 # 18 Y:2013 | 18 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $21,538 | $2,500 | Not Implemented |
UD0888 # 19 Y:2013 | 19 | 2013 | IMPROVE COMBUSTION CONTROL CAPABILITY | $262,538 | $700,000 | Not Implemented |
UD0888 # 20 Y:2013 | 20 | 2013 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $412 | $0 | Implemented |
UK1313 # 01 Y:2013 | 01 | 2013 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $396 | $5,000 | Implemented |
UD0888 # 12 Y:2013 | 12 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $20,092 | $0 | Implemented |
UL0178 # 11 Y:1997 | 11 | 1997 | ADOPT IN-HOUSE MATERIAL GENERATION | $2,900,000 | $1,500,000 | Not Implemented |
UL0178 # 10 Y:1997 | 10 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $13,400 | $30,000 | Implemented |
UL0178 # 09 Y:1997 | 09 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $36,000 | $0 | Not Implemented |
UL0178 # 08 Y:1997 | 08 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $260 | $0 | Not Implemented |
UL0178 # 07 Y:1997 | 07 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $500 | $0 | Not Implemented |
UL0178 # 06 Y:1997 | 06 | 1997 | OPTIMIZE PLANT POWER FACTOR | $2,200 | $4,270 | Not Implemented |
UL0178 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $348 | $2,270 | Implemented |
UL0178 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $425 | $14,240 | Not Implemented |