Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

104

matching recommendations
Reset
SIC 335 Nonferrous Rolling And Drawing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0334 # 06 Y:2007 06 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $910 $2 Not Implemented
BD0334 # 07 Y:2007 07 2007 USE SYNTHETIC LUBRICANT $3,966 $301 Implemented
BD0334 # 08 Y:2007 08 2007 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,625 $24,551 Implemented
UD0721 # 01 Y:2005 01 2005 RECOVER MECHANICAL ENERGY $206,969 $413,938 Implemented
UD0721 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $30,010 $86,100 Implemented
UD0721 # 03 Y:2005 03 2005 REPAIR AND ELIMINATE STEAM LEAKS $11,745 $160 Implemented
UD0721 # 04 Y:2005 04 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,579 $12,000 Implemented
UD0721 # 05 Y:2005 05 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,580 $0 Implemented
UD0721 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,040 $11,100 Implemented
UD0721 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $2,714 $345 Not Implemented
UD0721 # 08 Y:2005 08 2005 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,229 $860 Not Implemented
UD0721 # 09 Y:2005 09 2005 INSULATE BARE EQUIPMENT $675 $1,820 Not Implemented
UD0721 # 10 Y:2005 10 2005 UPGRADE CONTROLS ON COMPRESSORS $614 $0 Not Implemented
UD0721 # 11 Y:2005 11 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $613 $420 Not Implemented
UD0721 # 12 Y:2005 12 2005 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS $560 $1,000 Not Implemented
UD0721 # 13 Y:2005 13 2005 USE RADIANT HEATER FOR SPOT HEATING $506 $1,897 Not Implemented
IC0040 # 01 Y:2002 01 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,248 $47,200 Not Implemented
IC0040 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,379 $23,767 Not Implemented
IC0040 # 03 Y:2002 03 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,978 $3,100 Implemented
IC0040 # 04 Y:2002 04 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,817 $0 Implemented
IC0040 # 05 Y:2002 05 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $5,341 $0 Not Implemented
IC0040 # 06 Y:2002 06 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $3,923 $5,500 Implemented
IC0040 # 07 Y:2002 07 2002 ADJUST BURNERS FOR EFFICIENT OPERATION $10,651 $2,640 Not Implemented
IC0040 # 08 Y:2002 08 2002 COVER OPEN TANKS $18,222 $3,181 Not Implemented
IC0040 # 09 Y:2002 09 2002 INSULATE BARE EQUIPMENT $1,281 $756 Not Implemented