Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,036
matching recommendationsSIC | 335 | Nonferrous Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0661 # 06 Y:1999 | 06 | 1999 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $25,103 | $30,600 | Implemented |
TN0661 # 07 Y:1999 | 07 | 1999 | METER WASTE WATER | $13,500 | $3,700 | Not Implemented |
TN0661 # 08 Y:1999 | 08 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $6,500 | $650 | Not Implemented |
AR0160 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,689 | $3,628 | Implemented |
AR0160 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $272 | $1,750 | Implemented |
AR0160 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,374 | $50 | Implemented |
AR0160 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,246 | $450 | Not Implemented |
AR0160 # 05 Y:1999 | 05 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $9,048 | $5,000 | Implemented |
AR0160 # 06 Y:1999 | 06 | 1999 | REDUCE SCRAP PRODUCTION | $120,000 | $80,000 | Implemented |
AR0160 # 07 Y:1999 | 07 | 1999 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $118,802 | $300 | Not Implemented |
UM0127 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,907 | $5,428 | Not Implemented |
UM0127 # 02 Y:1999 | 02 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $16,282 | $250 | Not Implemented |
UM0127 # 03 Y:1999 | 03 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,496 | $5,000 | Not Implemented |
UM0127 # 04 Y:1999 | 04 | 1999 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $30,552 | $35,000 | Not Implemented |
UM0127 # 05 Y:1999 | 05 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $12,705 | $13,600 | Not Implemented |
UL0207 # 01 Y:1998 | 01 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,709 | $120 | Implemented |
UL0207 # 02 Y:1998 | 02 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,492 | $20 | Implemented |
UL0207 # 03 Y:1998 | 03 | 1998 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $74,500 | $163,800 | Not Implemented |
UL0207 # 04 Y:1998 | 04 | 1998 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $6,000 | $1,320 | Not Implemented |
UL0207 # 05 Y:1998 | 05 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $306,800 | $117,500 | Implemented |
MS0120 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,885 | $881 | Implemented |
MS0120 # 02 Y:1998 | 02 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,972 | $5,703 | Implemented |
MS0120 # 03 Y:1998 | 03 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,002 | $5,805 | Not Implemented |
MS0120 # 04 Y:1998 | 04 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,888 | $6,000 | Not Implemented |
MS0120 # 05 Y:1998 | 05 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,417 | $1,000 | Implemented |