Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

76

matching recommendations
Reset
SIC 335 Nonferrous Rolling And Drawing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0681 # 07 Y:1999 07 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $1,970 $1,950 Not Implemented
GT0681 # 06 Y:1999 06 1999 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $8,596 $2,360 Not Implemented
GT0681 # 05 Y:1999 05 1999 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $12,917 $4,800 Implemented
GT0681 # 04 Y:1999 04 1999 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $1,667 $600 Not Implemented
GT0681 # 03 Y:1999 03 1999 TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS $6,800 $0 Not Implemented
GT0681 # 11 Y:1999 11 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,431 $57,365 Not Implemented
GT0681 # 02 Y:1999 02 1999 ADJUST BURNERS FOR EFFICIENT OPERATION $45,788 $0 Not Implemented
GT0681 # 01 Y:1999 01 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $10,162 $0 Not Implemented
GT0681 # 08 Y:1999 08 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $5,540 $6,700 Not Implemented
GT0681 # 09 Y:1999 09 1999 USE LESS WASTEFUL PACKAGING $1,024 $3,500 Not Implemented
GT0681 # 10 Y:1999 10 1999 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $125,800 $64,000 Not Implemented
GT0681 # 12 Y:1999 12 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,768 $6,225 Not Implemented
UL0237 # 03 Y:1999 03 1999 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $5,309 $0 Not Implemented
UL0237 # 02 Y:1999 02 1999 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $11,512 $0 Implemented
UL0237 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,611 $100 Not Implemented
UF0233 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,649 $320 Implemented
UF0233 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,146 $20,484 Not Implemented
UF0233 # 07 Y:1999 07 1999 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $225 $210 Not Implemented
UF0233 # 05 Y:1999 05 1999 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $10,287 $14,925 Implemented
UF0233 # 06 Y:1999 06 1999 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $33,600 $0 Implemented
UF0233 # 04 Y:1999 04 1999 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $7,433 $3,905 Not Implemented
UF0233 # 02 Y:1999 02 1999 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $1,008 $750 Implemented
GT0668 # 08 Y:1999 08 1999 DEVELOP STANDARD OPERATING PROCEDURES $1,449,000 $234,000 Implemented
GT0668 # 06 Y:1999 06 1999 REMOVE SLUDGE FROM TANKS ON A REGULAR BASIS $48,977 $25,000 Not Implemented
GT0668 # 05 Y:1999 05 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,662 $345 Implemented