Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
261
matching recommendationsSIC | 3351 | Copper Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0400 # 05 Y:2015 | 05 | 2015 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $30,027 | $5,000 | Not Implemented |
LE0400 # 06 Y:2015 | 06 | 2015 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $27,922 | $10,500 | Not Implemented |
LE0400 # 07 Y:2015 | 07 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,457 | $3,025 | Implemented |
LE0400 # 08 Y:2015 | 08 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $26,074 | $35,000 | Not Implemented |
LE0400 # 09 Y:2015 | 09 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,334 | $16,500 | Implemented |
TT0159 # 01 Y:2015 | 01 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $31,644 | $3,000 | Implemented |
TT0159 # 02 Y:2015 | 02 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $19,647 | $20,000 | Not Implemented |
TT0159 # 03 Y:2015 | 03 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $17,175 | $38,170 | Not Implemented |
TT0159 # 04 Y:2015 | 04 | 2015 | INSTALL SPECTRAL REFLECTORS / DELAMP | $8,659 | $700 | Not Implemented |
TT0159 # 05 Y:2015 | 05 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,329 | $63 | Not Implemented |
TT0159 # 06 Y:2015 | 06 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,756 | $7,500 | Not Implemented |
TT0159 # 07 Y:2015 | 07 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $2,995 | $1,070 | Implemented |
TT0159 # 08 Y:2015 | 08 | 2015 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,187 | $500 | Implemented |
TT0159 # 09 Y:2015 | 09 | 2015 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,816 | $1,000 | Not Implemented |
SU0380 # 08 Y:2015 | 08 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,312 | $14,040 | Not Implemented |
SU0380 # 09 Y:2015 | 09 | 2015 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $583 | $1,743 | Not Implemented |
SU0380 # 01 Y:2015 | 01 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $22,610 | $0 | Implemented |
SU0380 # 02 Y:2015 | 02 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $22,134 | $0 | Not Implemented |
SU0380 # 03 Y:2015 | 03 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,172 | $0 | Implemented |
SU0380 # 05 Y:2015 | 05 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,359 | $0 | Implemented |
SU0380 # 04 Y:2015 | 04 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,751 | $0 | Implemented |
SU0380 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,620 | $805 | Implemented |
SU0380 # 06 Y:2015 | 06 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,708 | $1,340 | Implemented |
MZ0121 # 05 Y:2013 | 05 | 2013 | USE SYNTHETIC LUBRICANT | $4,308 | $56 | Implemented |
MZ0121 # 04 Y:2013 | 04 | 2013 | INSTALL SPECTRAL REFLECTORS / DELAMP | $5,476 | $5,441 | Implemented |