Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 3351 | Copper Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0574 # 07 Y:2005 | 07 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $960 | $0 | Implemented |
MA0574 # 06 Y:2005 | 06 | 2005 | INSULATE BARE EQUIPMENT | $2,911 | $5,770 | Implemented |
MA0574 # 05 Y:2005 | 05 | 2005 | INSULATE BARE EQUIPMENT | $3,466 | $1,801 | Implemented |
MA0574 # 04 Y:2005 | 04 | 2005 | OPTIMIZE PLANT POWER FACTOR | $20,725 | $20,215 | Not Implemented |
MA0574 # 03 Y:2005 | 03 | 2005 | BURN A LESS EXPENSIVE GRADE OF FUEL | $349,295 | $54,400 | Not Implemented |
MA0574 # 02 Y:2005 | 02 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $140,952 | $230,000 | Implemented |
MA0574 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $179,823 | $140,865 | Implemented |
MA0322 # 02 Y:1995 | 02 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $20,120 | $1,500 | Implemented |
MA0322 # 09 Y:1995 | 09 | 1995 | RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE | $28,494 | $57,500 | Not Implemented |
MA0322 # 08 Y:1995 | 08 | 1995 | USE OTHER WASTE CONCENTRATION METHODS | $61,150 | $85,000 | Implemented |
MA0322 # 07 Y:1995 | 07 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $384 | $945 | Implemented |
MA0322 # 06 Y:1995 | 06 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $684 | $578 | Not Implemented |
MA0322 # 05 Y:1995 | 05 | 1995 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,750 | $500 | Not Implemented |
MA0322 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,082 | $17,946 | Implemented |
MA0322 # 03 Y:1995 | 03 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,158 | $2,200 | Implemented |
MA0322 # 01 Y:1995 | 01 | 1995 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $62,376 | $150,000 | Not Implemented |
MA0217 # 10 Y:1991 | 10 | 1991 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $920 | $1,839 | Not Implemented |
MA0217 # 09 Y:1991 | 09 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $998 | $0 | Not Implemented |
MA0217 # 08 Y:1991 | 08 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,370 | $0 | Not Implemented |
MA0217 # 07 Y:1991 | 07 | 1991 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,777 | $3,874 | Not Implemented |
MA0217 # 06 Y:1991 | 06 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,199 | $0 | Not Implemented |
MA0217 # 05 Y:1991 | 05 | 1991 | REDUCE FLUID FLOW RATES | $8,252 | $330 | Not Implemented |
MA0217 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,357 | $30,000 | Not Implemented |
MA0217 # 03 Y:1991 | 03 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,453 | $1,500 | Not Implemented |
MA0217 # 02 Y:1991 | 02 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,862 | $19,305 | Not Implemented |