Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
98
matching recommendationsSIC | 3354 | Aluminum Extruded Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0276 # 05 Y:2001 | 05 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,279 | $10,000 | Not Implemented |
SD0276 # 04 Y:2001 | 04 | 2001 | INSULATE BARE EQUIPMENT | $419 | $250 | Not Implemented |
SD0276 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,529 | $320 | Not Implemented |
SD0276 # 02 Y:2001 | 02 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $469 | $100 | Not Implemented |
SD0276 # 01 Y:2001 | 01 | 2001 | USE PHOTOCELL CONTROLS | $3,062 | $1,000 | Not Implemented |
SD0250 # 07 Y:2000 | 07 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $97,460 | $135,000 | Not Implemented |
SD0250 # 01 Y:2000 | 01 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $45,106 | $210,000 | Not Implemented |
SD0250 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $44,752 | $600 | Implemented |
SD0250 # 03 Y:2000 | 03 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,942 | $4,100 | Not Implemented |
SD0250 # 04 Y:2000 | 04 | 2000 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $8,901 | $40,000 | Not Implemented |
SD0250 # 05 Y:2000 | 05 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $3,256 | $8,000 | Not Implemented |
SD0250 # 06 Y:2000 | 06 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $148,200 | $8,000 | Not Implemented |
SD0250 # 08 Y:2000 | 08 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $11,240 | $7,900 | Not Implemented |
SD0250 # 09 Y:2000 | 09 | 2000 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $5,000 | $12,500 | Not Implemented |
SD0250 # 10 Y:2000 | 10 | 2000 | SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED | $700 | $0 | Not Implemented |
SD0256 # 01 Y:2000 | 01 | 2000 | INSTALL SKYLIGHTS | $18,038 | $27,000 | Implemented |
SD0256 # 02 Y:2000 | 02 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,703 | $7,230 | Implemented |
SD0256 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $205,696 | $64,500 | Not Implemented |
SD0256 # 04 Y:2000 | 04 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,732 | $5,400 | Not Implemented |
SD0256 # 05 Y:2000 | 05 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $290,738 | $0 | Implemented |
SD0162 # 15 Y:1997 | 15 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $26,004 | $25,000 | Implemented |
SD0162 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,580 | $53,210 | Implemented |
SD0162 # 02 Y:1997 | 02 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $242,027 | $70,000 | Not Implemented |
SD0162 # 03 Y:1997 | 03 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $198,103 | $70,000 | Not Implemented |
SD0162 # 04 Y:1997 | 04 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $155,879 | $298,500 | Not Implemented |