Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
101
matching recommendationsSIC | 3355 | Aluminum Rolling And Drawing, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0280 # 01 Y:2003 | 01 | 2003 | ADJUST BURNERS FOR EFFICIENT OPERATION | $143,927 | $209,000 | Not Implemented |
WV0280 # 02 Y:2003 | 02 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $78,750 | $1,000 | Implemented |
WV0280 # 03 Y:2003 | 03 | 2003 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $63,438 | $8,180 | Not Implemented |
WV0280 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $27,160 | $750 | Implemented |
WV0280 # 05 Y:2003 | 05 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $23,943 | $45,000 | Not Implemented |
WV0280 # 06 Y:2003 | 06 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,252 | $750 | Implemented |
WV0280 # 07 Y:2003 | 07 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,348 | $100 | Implemented |
WV0280 # 08 Y:2003 | 08 | 2003 | BURN WASTE OIL FOR HEAT | $4,718 | $3,500 | Not Implemented |
WV0280 # 09 Y:2003 | 09 | 2003 | USE SYNTHETIC LUBRICANT | $4,705 | $250 | Implemented |
WV0280 # 10 Y:2003 | 10 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,633 | $0 | Not Implemented |
WV0280 # 11 Y:2003 | 11 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,080 | $477 | Implemented |
WV0280 # 12 Y:2003 | 12 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,953 | $7,230 | Implemented |
SF0090 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $348 | $577 | Implemented |
SF0090 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,366 | $13,620 | Implemented |
SF0090 # 03 Y:1996 | 03 | 1996 | INSULATE BARE EQUIPMENT | $8,425 | $3,900 | Implemented |
SF0090 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $833 | $0 | Implemented |
SF0090 # 05 Y:1996 | 05 | 1996 | USE SYNTHETIC LUBRICANT | $434 | $525 | Implemented |
SF0090 # 06 Y:1996 | 06 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,880 | $500 | Implemented |
SF0090 # 07 Y:1996 | 07 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $981 | $0 | Implemented |
UD0072 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,588 | $581 | Implemented |
UD0072 # 02 Y:1983 | 02 | 1983 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $71,594 | $288,000 | Not Implemented |
UD0072 # 03 Y:1983 | 03 | 1983 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,416 | $518 | Implemented |
UD0072 # 04 Y:1983 | 04 | 1983 | UPGRADE OBSOLETE EQUIPMENT | $5,762 | $20,000 | Not Implemented |
UD0072 # 05 Y:1983 | 05 | 1983 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $174 | $0 | Implemented |
UD0072 # 06 Y:1983 | 06 | 1983 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $88,910 | $155,000 | Not Implemented |