Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

21

matching recommendations
Reset
SIC 336 Nonferrous Foundries (castings)
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UW0018 # 05 Y:2008 05 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,037 $2,775 Not Implemented
UW0018 # 04 Y:2008 04 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,375 $4,328 Not Implemented
UW0018 # 03 Y:2008 03 2008 USE OPTIMUM THICKNESS INSULATION $9,391 $39,900 Not Implemented
UW0018 # 02 Y:2008 02 2008 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $12,434 $34,000 Not Implemented
UW0018 # 01 Y:2008 01 2008 $55,734 $72,000 Not Implemented
OR0509 # 04 Y:2006 04 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $660 $240 Implemented
OR0509 # 09 Y:2006 09 2006 $6,400 $22,000 Not Implemented
OR0509 # 08 Y:2006 08 2006 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,200 $3,000 Implemented
OR0509 # 07 Y:2006 07 2006 UPGRADE CONTROLS ON COMPRESSORS $7,000 $11,000 Implemented
OR0509 # 06 Y:2006 06 2006 INSULATE BARE EQUIPMENT $3,000 $1,200 Not Implemented
OR0509 # 05 Y:2006 05 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $1,300 $650 Not Implemented
OR0509 # 03 Y:2006 03 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,200 $2,250 Implemented
OR0509 # 02 Y:2006 02 2006 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $58,000 $6,800 Implemented
OR0509 # 01 Y:2006 01 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,900 $5,000 Implemented
OR0352 # 01 Y:1999 01 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $60,160 $81,250 Not Implemented
OR0352 # 07 Y:1999 07 1999 $2,430 $0 Not Implemented
OR0352 # 06 Y:1999 06 1999 COVER OPEN TANKS $2,130 $5,385 Not Implemented
OR0352 # 05 Y:1999 05 1999 COVER OPEN TANKS $1,940 $870 Not Implemented
OR0352 # 04 Y:1999 04 1999 USE OPTIMUM THICKNESS INSULATION $3,970 $950 Not Implemented
OR0352 # 03 Y:1999 03 1999 OPTIMIZE PLANT POWER FACTOR $9,819 $8,400 Not Implemented
OR0352 # 02 Y:1999 02 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,270 $3,200 Not Implemented