Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
114
matching recommendationsSIC | 3363 | Aluminum Die-castings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0343 # 02 Y:1999 | 02 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,616 | $94,400 | Not Implemented |
WI0343 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,468 | $60 | Implemented |
WI0343 # 04 Y:1999 | 04 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,053 | $9,000 | Not Implemented |
WI0343 # 05 Y:1999 | 05 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $3,188 | $8,500 | Not Implemented |
WI0343 # 06 Y:1999 | 06 | 1999 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $1,792 | $0 | Not Implemented |
WI0343 # 07 Y:1999 | 07 | 1999 | INSTALL OCCUPANCY SENSORS | $1,203 | $1,900 | Not Implemented |
WI0343 # 08 Y:1999 | 08 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $415 | $203 | Not Implemented |
WI0343 # 09 Y:1999 | 09 | 1999 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $680 | $0 | Not Implemented |
WI0295 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $119,785 | $0 | n/a |
WI0295 # 02 Y:1997 | 02 | 1997 | MAINTAIN/ENLARGE A STOCK OF SPARE PARTS | $68,700 | $0 | n/a |
WI0295 # 03 Y:1997 | 03 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $14,566 | $0 | n/a |
WI0295 # 04 Y:1997 | 04 | 1997 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $6,488 | $10,000 | n/a |
WI0295 # 05 Y:1997 | 05 | 1997 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $822 | $1,010 | n/a |
WI0295 # 06 Y:1997 | 06 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $807 | $500 | n/a |
WI0295 # 07 Y:1997 | 07 | 1997 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $617 | $0 | n/a |
WI0295 # 08 Y:1997 | 08 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $453 | $0 | n/a |
WI0225 # 01 Y:1994 | 01 | 1994 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $19,333 | $0 | Not Implemented |
WI0225 # 02 Y:1994 | 02 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,987 | $0 | Not Implemented |
WI0225 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,909 | $1,280 | Implemented |
WI0225 # 04 Y:1994 | 04 | 1994 | INSULATE BARE EQUIPMENT | $2,110 | $1,365 | Implemented |
WI0225 # 05 Y:1994 | 05 | 1994 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $291,000 | $100,000 | Not Implemented |
WI0225 # 06 Y:1994 | 06 | 1994 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $4,870 | $6,000 | Not Implemented |
WI0153 # 01 Y:1992 | 01 | 1992 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $19,612 | $0 | Not Implemented |
WI0153 # 02 Y:1992 | 02 | 1992 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $7,027 | $15,000 | Not Implemented |
WI0153 # 03 Y:1992 | 03 | 1992 | OPTIMIZE PLANT POWER FACTOR | $5,209 | $9,758 | Implemented |