Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 339 | Miscellaneous Primary Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0373 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,560 | $8,230 | Not Implemented |
AS0373 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $504 | $456 | Not Implemented |
AS0373 # 03 Y:2004 | 03 | 2004 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $337 | $1,400 | Not Implemented |
AS0373 # 04 Y:2004 | 04 | 2004 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $28,518 | $60,100 | Not Implemented |
AS0373 # 05 Y:2004 | 05 | 2004 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $1,794 | $3,500 | Not Implemented |
AS0166 # 11 Y:1996 | 11 | 1996 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $12,118 | $14,500 | Not Implemented |
AS0166 # 10 Y:1996 | 10 | 1996 | USE PHOTOCELL CONTROLS | $8,675 | $1,733 | Not Implemented |
AS0166 # 09 Y:1996 | 09 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $499 | $2,866 | Not Implemented |
AS0166 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,744 | $8,998 | Not Implemented |
AS0166 # 07 Y:1996 | 07 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,263 | $6,650 | Not Implemented |
AS0166 # 06 Y:1996 | 06 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $43,430 | $49,070 | Not Implemented |
AS0166 # 05 Y:1996 | 05 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,165 | $0 | Not Implemented |
AS0166 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,874 | $24,246 | Not Implemented |
AS0166 # 03 Y:1996 | 03 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $14,416 | $21,900 | Not Implemented |
AS0166 # 02 Y:1996 | 02 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,122 | $200 | Not Implemented |
AS0166 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,487 | $550 | Not Implemented |
AS0166 # 12 Y:1996 | 12 | 1996 | MINIMIZE WATER USAGE | $11,176 | $18,000 | Not Implemented |
AS0066 # 09 Y:1992 | 09 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,623 | $200 | Implemented |
AS0066 # 08 Y:1992 | 08 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $739 | $500 | Implemented |
AS0066 # 07 Y:1992 | 07 | 1992 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $384 | $800 | Implemented |
AS0066 # 06 Y:1992 | 06 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,845 | $0 | Implemented |
AS0066 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,921 | $7,200 | Implemented |
AS0066 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,140 | $7,221 | Implemented |
AS0066 # 03 Y:1992 | 03 | 1992 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,062 | $4,836 | Implemented |
AS0066 # 02 Y:1992 | 02 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,749 | $0 | Implemented |