Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,047
matching recommendationsSIC | 339 | Miscellaneous Primary Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0234 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,603 | $120,000 | Implemented |
UM0234 # 05 Y:2003 | 05 | 2003 | COVER OPEN TANKS | $8,523 | $2,000 | Not Implemented |
UM0234 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,198 | $5,219 | Not Implemented |
IC0044 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,388 | $10,093 | Implemented |
IC0044 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,542 | $12,107 | Implemented |
IC0044 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $845 | $1,327 | Implemented |
IC0044 # 04 Y:2002 | 04 | 2002 | DISCONNECT BALLASTS | $162 | $213 | Implemented |
IC0044 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $1,250 | $2,401 | Not Implemented |
IC0044 # 06 Y:2002 | 06 | 2002 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $610 | $534 | Implemented |
IC0044 # 07 Y:2002 | 07 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,860 | $0 | Implemented |
LM0045 # 01 Y:2002 | 01 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,878 | $5,000 | Not Implemented |
LM0045 # 02 Y:2002 | 02 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,317 | $1,000 | Not Implemented |
LM0045 # 03 Y:2002 | 03 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,903 | $0 | Implemented |
LM0045 # 04 Y:2002 | 04 | 2002 | USE EVAPORATION TO CONCENTRATE MATERIAL | $3,478 | $5,500 | Implemented |
LM0045 # 05 Y:2002 | 05 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $37,050 | $11,250 | Implemented |
LM0045 # 06 Y:2002 | 06 | 2002 | ADVERTISE PRODUCT OR SERVICE | $198,750 | $2,000 | Not Implemented |
LM0045 # 07 Y:2002 | 07 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $176,517 | $2,000 | Not Implemented |
UM0217 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $396 | $75 | Implemented |
UM0217 # 02 Y:2002 | 02 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $310 | $600 | Implemented |
UM0217 # 03 Y:2002 | 03 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $800 | $1,170 | Not Implemented |
UM0217 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $290 | $680 | Implemented |
UM0217 # 05 Y:2002 | 05 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,326 | $2,100 | Not Implemented |
UM0217 # 06 Y:2002 | 06 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $300 | $50 | Not Implemented |
UM0217 # 07 Y:2002 | 07 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $2,860 | $2,500 | Implemented |
UM0217 # 08 Y:2002 | 08 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $2,050 | $1,350 | Implemented |