Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 339 | Miscellaneous Primary Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0531 # 07 Y:2016 | 07 | 2016 | USE SAND FOR OTHER PURPOSES (EG CONSTRUCTION FILL, COVER FOR MUNICIPAL LANDFILLS) | $2,730 | $2,795 | Not Implemented |
WV0531 # 06 Y:2016 | 06 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,891 | $8,624 | Implemented |
WV0531 # 05 Y:2016 | 05 | 2016 | INSTALL SET-BACK TIMERS | $4,942 | $0 | Implemented |
WV0531 # 04 Y:2016 | 04 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,464 | $4,100 | Implemented |
WV0531 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $12,371 | $25,305 | Implemented |
WV0531 # 10 Y:2016 | 10 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $256 | $649 | Implemented |
WV0531 # 02 Y:2016 | 02 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,039 | $63,000 | Not Implemented |
WV0531 # 09 Y:2016 | 09 | 2016 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $956 | $1,000 | Implemented |
WV0531 # 08 Y:2016 | 08 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,225 | $4,010 | Implemented |
WV0531 # 01 Y:2016 | 01 | 2016 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $19,064 | $33,000 | Not Implemented |
TT0177 # 04 Y:2016 | 04 | 2016 | INSULATE BARE EQUIPMENT | $2,669 | $1,720 | Not Implemented |
TT0177 # 09 Y:2016 | 09 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $108 | $23 | Not Implemented |
TT0177 # 08 Y:2016 | 08 | 2016 | USE COMPRESSOR AIR FILTERS | $338 | $75 | Implemented |
TT0177 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $663 | $150 | Implemented |
TT0177 # 06 Y:2016 | 06 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,002 | $1,400 | Implemented |
TT0177 # 05 Y:2016 | 05 | 2016 | OPTIMIZE PLANT POWER FACTOR | $1,603 | $5,250 | Not Implemented |
TT0177 # 03 Y:2016 | 03 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,803 | $500 | Not Implemented |
TT0177 # 02 Y:2016 | 02 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $6,467 | $250 | Not Implemented |
TT0177 # 01 Y:2016 | 01 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,244 | $15,800 | Not Implemented |
SD0525 # 01 Y:2016 | 01 | 2016 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $11,264 | $750 | Not Implemented |
SD0525 # 08 Y:2016 | 08 | 2016 | INSULATE BARE EQUIPMENT | $1,494 | $527 | Not Implemented |
SD0525 # 06 Y:2016 | 06 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,406 | $1,200 | Not Implemented |
SD0525 # 05 Y:2016 | 05 | 2016 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $2,666 | $7,316 | Not Implemented |
SD0525 # 04 Y:2016 | 04 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,051 | $2,510 | Not Implemented |
SD0525 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,617 | $7,417 | Not Implemented |