IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

447

matching recommendations
Reset
SIC 3399 Primary Metal Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0176 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,095 $13,007 Not Implemented
WI0452 # 01 Y:2003 01 2003 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $54,337 $72,000 n/a
WI0452 # 02 Y:2003 02 2003 BURN WASTE OIL FOR HEAT $44,636 $30,000 Not Implemented
WI0452 # 03 Y:2003 03 2003 UPGRADE CONTROLS ON COMPRESSORS $5,692 $12,000 Not Implemented
WI0452 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $4,850 $2,700 Not Implemented
WI0452 # 05 Y:2003 05 2003 REPLACE CLOTH RAGS WITH PAPER TOWELS $4,710 $0 Not Implemented
WI0452 # 06 Y:2003 06 2003 INSTALL TIMERS AND/OR THERMOSTATS $4,063 $1,000 Not Implemented
WI0452 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,926 $8,580 Not Implemented
WI0452 # 08 Y:2003 08 2003 USE OPTIMUM THICKNESS INSULATION $1,592 $687 Not Implemented
LE0165 # 01 Y:2003 01 2003 INSULATE BARE EQUIPMENT $8,970 $1,440 Implemented
LE0165 # 02 Y:2003 02 2003 INSTALL OCCUPANCY SENSORS $2,288 $500 Not Implemented
LE0165 # 03 Y:2003 03 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,356 $263 Not Implemented
LE0165 # 04 Y:2003 04 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $468 $0 Implemented
LE0165 # 05 Y:2003 05 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $498 $0 Not Implemented
LE0165 # 06 Y:2003 06 2003 MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS $3,608 $500 Not Implemented
LE0157 # 01 Y:2003 01 2003 INSTALL BACK-UP EQUIPMENT $125,000 $30,500 Not Implemented
LE0157 # 02 Y:2003 02 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $4,881 $0 Not Implemented
LE0157 # 03 Y:2003 03 2003 INSTALL OCCUPANCY SENSORS $636 $825 Not Implemented
LE0157 # 04 Y:2003 04 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,858 $6,500 Not Implemented
LE0157 # 05 Y:2003 05 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,513 $0 Not Implemented
LE0157 # 06 Y:2003 06 2003 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $769 $200 Not Implemented
UM0213 # 01 Y:2002 01 2002 RECOVER WASTE HEAT FROM EQUIPMENT $40,905 $1,000 Not Implemented
UM0213 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $35,927 $71,714 Implemented
UM0213 # 03 Y:2002 03 2002 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $23,514 $500 Implemented
UM0213 # 04 Y:2002 04 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $22,460 $3,600 Implemented