Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
595
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0414 # 06 Y:2002 | 06 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,971 | $0 | Not Implemented |
WI0414 # 07 Y:2002 | 07 | 2002 | INSTALL OCCUPANCY SENSORS | $1,071 | $2,400 | Implemented |
WI0414 # 08 Y:2002 | 08 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $754 | $350 | Implemented |
WI0407 # 01 Y:2001 | 01 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $26,600 | $0 | n/a |
WI0407 # 02 Y:2001 | 02 | 2001 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $6,632 | $12,000 | n/a |
WI0407 # 03 Y:2001 | 03 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,562 | $100 | n/a |
WI0407 # 04 Y:2001 | 04 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,796 | $3,760 | n/a |
WI0407 # 05 Y:2001 | 05 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $4,274 | $600 | n/a |
WI0407 # 06 Y:2001 | 06 | 2001 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $751 | $0 | n/a |
WI0407 # 07 Y:2001 | 07 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $486 | $640 | n/a |
WI0407 # 08 Y:2001 | 08 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289 | $0 | n/a |
WI0406 # 01 Y:2001 | 01 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,841 | $0 | Implemented |
WI0406 # 02 Y:2001 | 02 | 2001 | OPTIMIZE PLANT POWER FACTOR | $7,981 | $14,550 | Not Implemented |
WI0406 # 03 Y:2001 | 03 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $3,632 | $600 | Not Implemented |
WI0406 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $3,556 | $3,880 | Not Implemented |
WI0406 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,901 | $0 | Not Implemented |
WI0406 # 06 Y:2001 | 06 | 2001 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,063 | $0 | Not Implemented |
WI0406 # 07 Y:2001 | 07 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $392 | $556 | Not Implemented |
WI0362 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,236 | $1,860 | Not Implemented |
WI0362 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,550 | $740 | Not Implemented |
WI0362 # 03 Y:2000 | 03 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,619 | $16,000 | Not Implemented |
WI0362 # 04 Y:2000 | 04 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,741 | $14,500 | Not Implemented |
WI0362 # 05 Y:2000 | 05 | 2000 | TREAT AND REUSE RINSE WATERS | $3,598 | $6,375 | Implemented |
WI0362 # 06 Y:2000 | 06 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,130 | $2,150 | Not Implemented |
WI0362 # 07 Y:2000 | 07 | 2000 | REUSE / RECYCLE/ SELL RUBBER PRODUCTS | $1,562 | $0 | Not Implemented |