Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,750
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0666 # 04 Y:2014 | 04 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,308 | $3,000 | Implemented |
AM0666 # 05 Y:2014 | 05 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,230 | $1,035 | Implemented |
AM0666 # 06 Y:2014 | 06 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,330 | $11 | Implemented |
AM0666 # 07 Y:2014 | 07 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $450 | $430 | Implemented |
AM0666 # 08 Y:2014 | 08 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $420 | $500 | Implemented |
AM0661 # 01 Y:2014 | 01 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,760 | $0 | Implemented |
AM0661 # 02 Y:2014 | 02 | 2014 | OPTIMIZE PLANT POWER FACTOR | $3,420 | $10,310 | Not Implemented |
AM0661 # 03 Y:2014 | 03 | 2014 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,170 | $0 | Implemented |
AM0661 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,440 | $1,500 | Implemented |
AM0661 # 05 Y:2014 | 05 | 2014 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $865 | $3,995 | Implemented |
AM0661 # 06 Y:2014 | 06 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $560 | $845 | Implemented |
AM0661 # 07 Y:2014 | 07 | 2014 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $540 | $0 | Implemented |
AM0661 # 08 Y:2014 | 08 | 2014 | USE SYNTHETIC LUBRICANT | $500 | $0 | Not Implemented |
AM0661 # 09 Y:2014 | 09 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $360 | $280 | Implemented |
AM0661 # 10 Y:2014 | 10 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $312 | $180 | Implemented |
OK0874 # 01 Y:2014 | 01 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $380 | $112 | Implemented |
OK0874 # 02 Y:2014 | 02 | 2014 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $3,364 | $1,568 | Implemented |
OK0874 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,682 | $0 | Implemented |
OK0874 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,847 | $980 | Implemented |
OK0874 # 05 Y:2014 | 05 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,899 | $21,005 | Not Implemented |
OK0874 # 06 Y:2014 | 06 | 2014 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $934 | $1,024 | Implemented |
AM0650 # 01 Y:2014 | 01 | 2014 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $17,640 | $0 | Implemented |
AM0650 # 02 Y:2014 | 02 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $31,250 | $10,000 | Implemented |
AM0650 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,060 | $1,200 | Implemented |
AM0650 # 04 Y:2014 | 04 | 2014 | OPTIMIZE PLANT POWER FACTOR | $2,335 | $6,805 | Not Implemented |