Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
746
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0484 # 01 Y:2001 | 01 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $8,050 | $8,660 | n/a |
CO0484 # 02 Y:2001 | 02 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $7,440 | $1,670 | n/a |
CO0484 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,610 | $390 | n/a |
CO0484 # 04 Y:2001 | 04 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,010 | $4,000 | n/a |
CO0484 # 05 Y:2001 | 05 | 2001 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $2,110 | $12,600 | n/a |
CO0484 # 06 Y:2001 | 06 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $870 | $30 | n/a |
CO0484 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $520 | $0 | n/a |
CO0484 # 08 Y:2001 | 08 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $34,130 | $7,350 | n/a |
CO0484 # 09 Y:2001 | 09 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $14,950 | $0 | n/a |
CO0484 # 10 Y:2001 | 10 | 2001 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $11,240 | $20,000 | n/a |
OR0391 # 01 Y:2001 | 01 | 2001 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $324,000 | $79,300 | Implemented |
OR0391 # 02 Y:2001 | 02 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,300 | $0 | Implemented |
OR0391 # 03 Y:2001 | 03 | 2001 | COMBINE UTILITY METERS | $8,935 | $24,325 | Not Implemented |
OR0391 # 04 Y:2001 | 04 | 2001 | OPTIMIZE PLANT POWER FACTOR | $2,855 | $8,000 | Not Implemented |
OR0391 # 05 Y:2001 | 05 | 2001 | INSTALL COMMON HEADER ON COMPRESSORS | $2,248 | $6,400 | Not Implemented |
SU0106 # 01 Y:2001 | 01 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,051 | $0 | Implemented |
SU0106 # 02 Y:2001 | 02 | 2001 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $399,407 | $1,400,000 | Not Implemented |
SU0106 # 03 Y:2001 | 03 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,947 | $2,241 | Not Implemented |
SU0106 # 04 Y:2001 | 04 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,158 | $500 | Implemented |
SU0106 # 05 Y:2001 | 05 | 2001 | OPTIMIZE PLANT POWER FACTOR | $3,243 | $10,210 | Implemented |
IC0007 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,050 | $2,125 | Implemented |
IC0007 # 02 Y:2001 | 02 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,195 | $25,250 | Not Implemented |
IC0007 # 03 Y:2001 | 03 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,066 | $195 | Implemented |
IC0007 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,387 | $18,965 | Not Implemented |
IC0007 # 05 Y:2001 | 05 | 2001 | INSTALL OCCUPANCY SENSORS | $94 | $372 | Not Implemented |