Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,620
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0298 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,304 | $0 | Implemented |
WV0298 # 09 Y:2004 | 09 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $736 | $705 | Implemented |
WV0298 # 10 Y:2004 | 10 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $794 | $1,825 | Not Implemented |
WV0298 # 11 Y:2004 | 11 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $762 | $750 | Implemented |
WV0298 # 12 Y:2004 | 12 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $565 | $1,000 | Not Implemented |
WV0298 # 13 Y:2004 | 13 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $461 | $360 | Implemented |
UD0697 # 01 Y:2004 | 01 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $36,804 | $0 | Implemented |
UD0697 # 02 Y:2004 | 02 | 2004 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $11,330 | $0 | Implemented |
UD0697 # 03 Y:2004 | 03 | 2004 | COVER OPEN TANKS | $5,579 | $3,590 | Not Implemented |
UD0697 # 04 Y:2004 | 04 | 2004 | REDUCE FLUID FLOW RATES | $2,950 | $0 | Implemented |
UD0697 # 05 Y:2004 | 05 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $2,868 | $770 | Not Implemented |
UD0697 # 06 Y:2004 | 06 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,816 | $10,786 | Not Implemented |
UD0697 # 07 Y:2004 | 07 | 2004 | USE PHOTOCELL CONTROLS | $2,756 | $11,325 | Not Implemented |
UD0697 # 08 Y:2004 | 08 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,294 | $100 | Not Implemented |
UD0697 # 09 Y:2004 | 09 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,414 | $100 | Not Implemented |
UD0697 # 10 Y:2004 | 10 | 2004 | REDUCE VENTILATION AIR | $804 | $0 | Not Implemented |
UD0697 # 11 Y:2004 | 11 | 2004 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $782 | $0 | Implemented |
UD0697 # 12 Y:2004 | 12 | 2004 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $244 | $0 | Implemented |
UD0697 # 13 Y:2004 | 13 | 2004 | INSULATE BARE EQUIPMENT | $240 | $91 | Implemented |
UD0697 # 14 Y:2004 | 14 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $49 | $0 | Not Implemented |
UD0694 # 01 Y:2004 | 01 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $318,395 | $324,700 | Not Implemented |
UD0694 # 02 Y:2004 | 02 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $295,125 | $0 | Implemented |
UD0694 # 03 Y:2004 | 03 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $117,513 | $80,244 | Not Implemented |
UD0694 # 04 Y:2004 | 04 | 2004 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $57,990 | $114,000 | Not Implemented |
UD0694 # 05 Y:2004 | 05 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $33,763 | $51,348 | Implemented |