Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
436
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0450 # 06 Y:2012 | 06 | 2012 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $632 | $2,035 | Not Implemented |
NC0450 # 07 Y:2012 | 07 | 2012 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $113,534 | $25,000 | Implemented |
NC0450 # 08 Y:2012 | 08 | 2012 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $105,000 | $40,000 | Implemented |
NC0450 # 09 Y:2012 | 09 | 2012 | MAINTAIN CLEAN CONDITIONS BEFORE PAINTING | $38,389 | $30,000 | Implemented |
NC0450 # 10 Y:2012 | 10 | 2012 | IMPROVE SPACE COMFORT CONDITIONING | $4,739 | $8,000 | Not Implemented |
NC0431 # 01 Y:2011 | 01 | 2011 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,700 | $100 | Implemented |
NC0431 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,126 | $45,273 | Implemented |
NC0431 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $504 | $409 | Implemented |
NC0431 # 04 Y:2011 | 04 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,281 | $2,625 | Not Implemented |
NC0431 # 05 Y:2011 | 05 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $825 | $910 | Implemented |
NC0431 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $193 | $100 | Implemented |
NC0431 # 07 Y:2011 | 07 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $280 | $0 | Implemented |
NC0426 # 01 Y:2011 | 01 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,495 | $2,825 | Not Implemented |
NC0426 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $815 | $1,530 | Implemented |
NC0426 # 03 Y:2011 | 03 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,690 | $3,750 | Not Implemented |
NC0426 # 04 Y:2011 | 04 | 2011 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,171 | $4,700 | Not Implemented |
NC0426 # 05 Y:2011 | 05 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $302 | $25 | Implemented |
NC0426 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $98 | $100 | Implemented |
NC0426 # 07 Y:2011 | 07 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $5,569 | $21,550 | Not Implemented |
NC0401 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,940 | $7,800 | Implemented |
NC0401 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $845 | $200 | Implemented |
NC0401 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,947 | $6,200 | Implemented |
NC0401 # 07 Y:2010 | 07 | 2010 | INSTALL OCCUPANCY SENSORS | $5,761 | $3,750 | Implemented |
NC0401 # 03 Y:2010 | 03 | 2010 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $5,578 | $0 | Implemented |
NC0401 # 02 Y:2010 | 02 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,833 | $0 | Implemented |