Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,750
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0118 # 15 Y:1998 | 15 | 1998 | MINIMIZE WATER USAGE | $982 | $1,395 | Not Implemented |
BD0118 # 16 Y:1998 | 16 | 1998 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $2,340 | $2,000 | Not Implemented |
BD0118 # 17 Y:1998 | 17 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $380 | $0 | Not Implemented |
WI0324 # 01 Y:1998 | 01 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,936 | $0 | Not Implemented |
WI0324 # 02 Y:1998 | 02 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $487 | $0 | Implemented |
WI0324 # 03 Y:1998 | 03 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,780 | $850 | Not Implemented |
WI0324 # 04 Y:1998 | 04 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,054 | $400 | Implemented |
WI0324 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $381 | $90 | Implemented |
WI0324 # 06 Y:1998 | 06 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $372 | $640 | Implemented |
WI0324 # 07 Y:1998 | 07 | 1998 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,039 | $0 | Not Implemented |
WI0318 # 01 Y:1998 | 01 | 1998 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $89,367 | $0 | Implemented |
WI0318 # 02 Y:1998 | 02 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,742 | $10,000 | Not Implemented |
WI0318 # 03 Y:1998 | 03 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,845 | $0 | Not Implemented |
WI0318 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $598 | $386 | Not Implemented |
WI0318 # 05 Y:1998 | 05 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $555 | $0 | Implemented |
WI0318 # 06 Y:1998 | 06 | 1998 | INSULATE BARE EQUIPMENT | $417 | $742 | Implemented |
WI0318 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $331 | $571 | Implemented |
BD0107 # 01 Y:1998 | 01 | 1998 | UPGRADE CONTROLS ON COMPRESSORS | $19,185 | $31,500 | Implemented |
BD0107 # 02 Y:1998 | 02 | 1998 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $2,679 | $6,000 | Not Implemented |
BD0107 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,897 | $1,000 | Not Implemented |
BD0107 # 04 Y:1998 | 04 | 1998 | INSTALL AUTOMATIC STACK DAMPER | $1,388 | $2,500 | Not Implemented |
BD0107 # 05 Y:1998 | 05 | 1998 | INSTALL OCCUPANCY SENSORS | $750 | $300 | Implemented |
BD0107 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $278 | $470 | Implemented |
BD0107 # 07 Y:1998 | 07 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $21,088 | $7,500 | Not Implemented |
BD0107 # 08 Y:1998 | 08 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,899 | $7,000 | Implemented |