Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,139

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ND0330 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $228 $320 Implemented
ND0330 # 03 Y:1999 03 1999 USE OPTIMUM TEMPERATURE $15 $10 Implemented
ND0330 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $3,950 $3,800 Implemented
ND0330 # 05 Y:1999 05 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,337 $1,000 Not Implemented
ND0330 # 06 Y:1999 06 1999 OPTIMIZE PLANT POWER FACTOR $5,430 $4,252 Implemented
ND0330 # 07 Y:1999 07 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $131 $350 Not Implemented
ND0330 # 08 Y:1999 08 1999 REDUCE OR ELIMINATE WASTE $1,067 $95 Implemented
ND0330 # 09 Y:1999 09 1999 MINIMIZE WATER USAGE $821 $960 Not Implemented
ND0330 # 10 Y:1999 10 1999 PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW $3,873 $17,271 Implemented
ND0330 # 11 Y:1999 11 1999 USE SYNTHETIC LUBRICANT $3,469 $1,375 Implemented
ND0330 # 12 Y:1999 12 1999 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,763 $750 Not Implemented
ND0330 # 13 Y:1999 13 1999 DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS $2,990 $250 Implemented
KU0523 # 01 Y:1999 01 1999 OPTIMIZE PLANT POWER FACTOR $7,490 $7,600 Not Implemented
KU0523 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,040 $2,050 Not Implemented
KU0523 # 03 Y:1999 03 1999 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,100 $560 Not Implemented
KU0523 # 04 Y:1999 04 1999 USE SYNTHETIC LUBRICANT $800 $1,530 Not Implemented
KU0523 # 05 Y:1999 05 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $740 $450 Not Implemented
KU0523 # 06 Y:1999 06 1999 DISTILL CONTAMINATED SOLVENTS FOR REUSE $4,740 $6,300 Not Implemented
DS0147 # 01 Y:1999 01 1999 INSTALL TIMERS AND/OR THERMOSTATS $4,412 $3,358 Not Implemented
DS0147 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $301 $343 Not Implemented
DS0147 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $635 $1,156 Not Implemented
DS0147 # 04 Y:1999 04 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,400 $4,365 Not Implemented
DS0147 # 05 Y:1999 05 1999 BURN WASTE OIL FOR HEAT $857 $1,695 Not Implemented
DS0147 # 06 Y:1999 06 1999 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $1,498 $2,832 Not Implemented
DS0147 # 07 Y:1999 07 1999 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $903 $0 Not Implemented