Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,775

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0595 # 06 Y:2000 06 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,855 $6,930 Implemented
OK0595 # 07 Y:2000 07 2000 INCREASE USE OF AUTOMATION $367,920 $150,000 Implemented
OK0595 # 08 Y:2000 08 2000 AUTOMATE FINISHING PROCESS $227,760 $30,000 Not Implemented
OK0595 # 09 Y:2000 09 2000 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM $36,400 $65,450 Not Implemented
AM0374 # 01 Y:2000 01 2000 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,510 $350 Not Implemented
AM0374 # 02 Y:2000 02 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,670 $910 Not Implemented
AM0374 # 03 Y:2000 03 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,080 $0 Not Implemented
AM0374 # 04 Y:2000 04 2000 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $1,010 $610 Implemented
AM0374 # 05 Y:2000 05 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $930 $78 Implemented
AM0374 # 06 Y:2000 06 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $470 $155 Implemented
SD0247 # 01 Y:2000 01 2000 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $11,396 $8,250 Not Implemented
SD0247 # 02 Y:2000 02 2000 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $6,905 $3,000 Not Implemented
SD0247 # 03 Y:2000 03 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,007 $0 Not Implemented
SD0247 # 04 Y:2000 04 2000 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $5,628 $3,000 Not Implemented
SD0247 # 05 Y:2000 05 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,279 $1,800 Not Implemented
SD0247 # 06 Y:2000 06 2000 INSULATE BARE EQUIPMENT $570 $1,030 Not Implemented
SD0247 # 07 Y:2000 07 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $3,440 $12,500 Not Implemented
SD0247 # 08 Y:2000 08 2000 CONTRACT A WOOD PALLET RECYCLING COMPANY $6,916 $0 Not Implemented
SD0247 # 09 Y:2000 09 2000 IMPROVE SPACE COMFORT CONDITIONING $32,000 $10,380 Not Implemented
KU0537 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $970 $1,480 Not Implemented
KU0537 # 02 Y:2000 02 2000 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $580 $0 Not Implemented
KU0537 # 03 Y:2000 03 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $400 $200 Not Implemented
KU0537 # 04 Y:2000 04 2000 METER WASTE WATER $2,980 $1,910 Not Implemented
KU0537 # 05 Y:2000 05 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $1,180 $1,740 Not Implemented
HO0229 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,928 $20,007 Not Implemented