Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,139
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0543 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,018 | $16,558 | Not Implemented |
UD0543 # 06 Y:1998 | 06 | 1998 | USE POWER DURING OFF-PEAK PERIODS | $1,660 | $0 | Implemented |
UD0542 # 01 Y:1998 | 01 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $183,600 | $0 | Implemented |
UD0542 # 02 Y:1998 | 02 | 1998 | RECOVER METALS FROM CASTING SAND | $21,000 | $4,800 | Not Implemented |
UD0542 # 03 Y:1998 | 03 | 1998 | USE POWER DURING OFF-PEAK PERIODS | $11,143 | $0 | Implemented |
UD0542 # 04 Y:1998 | 04 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $8,400 | $0 | Implemented |
UD0542 # 05 Y:1998 | 05 | 1998 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $8,000 | $17,000 | Not Implemented |
UD0542 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,513 | $14,128 | Implemented |
UD0542 # 07 Y:1998 | 07 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,236 | $20,000 | Not Implemented |
UD0542 # 08 Y:1998 | 08 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,053 | $0 | Not Implemented |
WI0319 # 01 Y:1998 | 01 | 1998 | INSTALL SENSORS TO DETECT DEFECTS | $69,212 | $63,760 | Not Implemented |
WI0319 # 02 Y:1998 | 02 | 1998 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $6,046 | $13,200 | Not Implemented |
WI0319 # 03 Y:1998 | 03 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,599 | $18,400 | Not Implemented |
WI0319 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,295 | $940 | Not Implemented |
WI0319 # 05 Y:1998 | 05 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,187 | $500 | Not Implemented |
WI0319 # 06 Y:1998 | 06 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $214 | $0 | Implemented |
DS0110 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,901 | $3,030 | Implemented |
DS0110 # 02 Y:1998 | 02 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $747 | $763 | Implemented |
DS0110 # 03 Y:1998 | 03 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $791 | $1,595 | Not Implemented |
DS0110 # 04 Y:1998 | 04 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $960 | $4,750 | Not Implemented |
DS0110 # 05 Y:1998 | 05 | 1998 | CONVERT TO ELECTROSTATIC POWDER COATING | $136,736 | $12,000 | Not Implemented |
DS0110 # 06 Y:1998 | 06 | 1998 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $2,574 | $12,130 | Not Implemented |
DS0110 # 07 Y:1998 | 07 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $7,270 | $1,200 | Implemented |
AS0220 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,134 | $9,231 | Not Implemented |
AS0220 # 02 Y:1998 | 02 | 1998 | INSTALL OCCUPANCY SENSORS | $519 | $525 | Not Implemented |