Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,133
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0086 # 06 Y:1996 | 06 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $569 | $1,467 | Not Implemented |
WV0086 # 07 Y:1996 | 07 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $303 | $523 | Not Implemented |
WV0086 # 08 Y:1996 | 08 | 1996 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $8,594 | $5,400 | Implemented |
UD0484 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $4,104 | $4,000 | Implemented |
UD0484 # 02 Y:1996 | 02 | 1996 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $60,000 | $0 | Not Implemented |
UD0484 # 03 Y:1996 | 03 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,391 | $-30,000 | Implemented |
UD0484 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,627 | $2,700 | Not Implemented |
UD0484 # 05 Y:1996 | 05 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,744 | $4,000 | Not Implemented |
UD0484 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,582 | $2,704 | Not Implemented |
WI0258 # 01 Y:1996 | 01 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $9,926 | $4,400 | Implemented |
WI0258 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,406 | $50,000 | Not Implemented |
WI0258 # 03 Y:1996 | 03 | 1996 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,447 | $0 | Implemented |
WI0258 # 04 Y:1996 | 04 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,690 | $1,600 | Implemented |
WI0258 # 05 Y:1996 | 05 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,800 | $0 | Not Implemented |
WI0258 # 06 Y:1996 | 06 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,107 | $500 | Not Implemented |
WV0085 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $962 | $6,073 | Implemented |
WV0085 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $779 | $3,050 | Implemented |
WV0085 # 03 Y:1996 | 03 | 1996 | USE SYNTHETIC LUBRICANT | $250 | $400 | Implemented |
WV0085 # 04 Y:1996 | 04 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,694 | $500 | Implemented |
WV0085 # 05 Y:1996 | 05 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $9,180 | $9,200 | Not Implemented |
MS0051 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,762 | $4,217 | Implemented |
MS0051 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,574 | $39,728 | Not Implemented |
MS0051 # 03 Y:1996 | 03 | 1996 | USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY | $1,724 | $7,665 | Not Implemented |
MS0051 # 04 Y:1996 | 04 | 1996 | USE RE-USABLE FILTERS | $900 | $1,500 | Not Implemented |
MS0051 # 05 Y:1996 | 05 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,048 | $20,000 | Not Implemented |