IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

291

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA3016 # 02 Y:2011 02 2011 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $3,721 $3,550 Not Implemented
UA3016 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,180 $1,500 Implemented
UA3016 # 04 Y:2011 04 2011 RECOVER WASTE HEAT FROM EQUIPMENT $7,387 $2,291 Not Implemented
UA3016 # 05 Y:2011 05 2011 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $6,784 $2,000 Not Implemented
UA0060 # 01 Y:2011 01 2011 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $10,956 $34,000 Not Implemented
UA0060 # 02 Y:2011 02 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $804 $2,040 Not Implemented
UA0060 # 03 Y:2011 03 2011 AIR CONDITION ONLY SPACE NECESSARY $20,888 $14,995 Not Implemented
UA3013 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $44,925 $31,378 Not Implemented
UA3013 # 02 Y:2011 02 2011 USE PHOTOCELL CONTROLS $1,196 $225 Not Implemented
UA3013 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $4,650 $7,410 Not Implemented
UA3013 # 04 Y:2011 04 2011 REDUCE FLUID FLOW RATES $6,480 $2,168 Not Implemented
UA3011 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,307 $26,402 Not Implemented
UA3011 # 02 Y:2011 02 2011 USE PHOTOCELL CONTROLS $575 $225 Implemented
UA3011 # 03 Y:2011 03 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $23,842 $5,000 Implemented
UA3011 # 04 Y:2011 04 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,087 $640 Not Implemented
UA3011 # 05 Y:2011 05 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $8,304 $1,800 Not Implemented
UA3011 # 06 Y:2011 06 2011 REPAIR AND ELIMINATE STEAM LEAKS $515 $1,030 Implemented
UA3011 # 07 Y:2011 07 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $7,440 $4,586 Not Implemented
UA3011 # 08 Y:2011 08 2011 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,373 $320 Not Implemented
UA3011 # 09 Y:2011 09 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,493 $70,000 Not Implemented
UA3011 # 10 Y:2011 10 2011 USE RADIANT HEATER FOR SPOT HEATING $13,650 $9,480 Not Implemented
UA3011 # 11 Y:2011 11 2011 INSTALL TIMERS AND/OR THERMOSTATS $366 $510 Implemented
UA3011 # 12 Y:2011 12 2011 INSTALL TIMERS AND/OR THERMOSTATS $843 $50 Implemented
UA3011 # 13 Y:2011 13 2011 INSULATE BARE EQUIPMENT $5,251 $1,503 Not Implemented
UA3004 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,609 $24,042 Not Implemented