Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

564

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0465 # 06 Y:2000 06 2000 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $4,090 $7,960 Implemented
CO0465 # 07 Y:2000 07 2000 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $280 $0 Not Implemented
CO0465 # 08 Y:2000 08 2000 EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME $6,930 $6,000 Not Implemented
CO0465 # 09 Y:2000 09 2000 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,460 $250 Not Implemented
CO0459 # 01 Y:2000 01 2000 TURN OFF EQUIPMENT WHEN NOT IN USE $7,950 $660 Not Implemented
CO0459 # 02 Y:2000 02 2000 USE DEMAND CONTROLLER OR LOAD SHEDDER $6,550 $7,500 Not Implemented
CO0459 # 03 Y:2000 03 2000 OPTIMIZE PLANT POWER FACTOR $6,420 $15,880 Implemented
CO0459 # 04 Y:2000 04 2000 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,670 $1,130 Not Implemented
CO0459 # 05 Y:2000 05 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,650 $2,070 Implemented
CO0459 # 06 Y:2000 06 2000 INSTALL OCCUPANCY SENSORS $440 $560 Not Implemented
CO0459 # 07 Y:2000 07 2000 INSULATE BARE EQUIPMENT $350 $80 Not Implemented
CO0459 # 08 Y:2000 08 2000 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $3,070 $9,130 Not Implemented
CO0459 # 09 Y:2000 09 2000 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $2,980 $0 Not Implemented
CO0459 # 10 Y:2000 10 2000 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $600 $0 Implemented
CO0457 # 01 Y:2000 01 2000 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,380 $7,500 Implemented
CO0457 # 02 Y:2000 02 2000 INSTALL OCCUPANCY SENSORS $1,340 $2,850 Not Implemented
CO0457 # 03 Y:2000 03 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $660 $0 Implemented
CO0457 # 04 Y:2000 04 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $660 $1,000 Implemented
CO0457 # 05 Y:2000 05 2000 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $1,880 $0 Not Implemented
CO0457 # 06 Y:2000 06 2000 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $320 $0 Implemented
CO0457 # 07 Y:2000 07 2000 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES $5,100 $1,510 Implemented
CO0441 # 01 Y:1999 01 1999 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,470 $2,000 Not Implemented
CO0441 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,366 $6,988 Not Implemented
CO0441 # 03 Y:1999 03 1999 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,490 $1,160 Not Implemented
CO0441 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,970 $200 Implemented