Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
564
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0465 # 06 Y:2000 | 06 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $4,090 | $7,960 | Implemented |
CO0465 # 07 Y:2000 | 07 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $280 | $0 | Not Implemented |
CO0465 # 08 Y:2000 | 08 | 2000 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $6,930 | $6,000 | Not Implemented |
CO0465 # 09 Y:2000 | 09 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,460 | $250 | Not Implemented |
CO0459 # 01 Y:2000 | 01 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,950 | $660 | Not Implemented |
CO0459 # 02 Y:2000 | 02 | 2000 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,550 | $7,500 | Not Implemented |
CO0459 # 03 Y:2000 | 03 | 2000 | OPTIMIZE PLANT POWER FACTOR | $6,420 | $15,880 | Implemented |
CO0459 # 04 Y:2000 | 04 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,670 | $1,130 | Not Implemented |
CO0459 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,650 | $2,070 | Implemented |
CO0459 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $440 | $560 | Not Implemented |
CO0459 # 07 Y:2000 | 07 | 2000 | INSULATE BARE EQUIPMENT | $350 | $80 | Not Implemented |
CO0459 # 08 Y:2000 | 08 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,070 | $9,130 | Not Implemented |
CO0459 # 09 Y:2000 | 09 | 2000 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $2,980 | $0 | Not Implemented |
CO0459 # 10 Y:2000 | 10 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $600 | $0 | Implemented |
CO0457 # 01 Y:2000 | 01 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,380 | $7,500 | Implemented |
CO0457 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $1,340 | $2,850 | Not Implemented |
CO0457 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $660 | $0 | Implemented |
CO0457 # 04 Y:2000 | 04 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $660 | $1,000 | Implemented |
CO0457 # 05 Y:2000 | 05 | 2000 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $1,880 | $0 | Not Implemented |
CO0457 # 06 Y:2000 | 06 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $320 | $0 | Implemented |
CO0457 # 07 Y:2000 | 07 | 2000 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $5,100 | $1,510 | Implemented |
CO0441 # 01 Y:1999 | 01 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,470 | $2,000 | Not Implemented |
CO0441 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,366 | $6,988 | Not Implemented |
CO0441 # 03 Y:1999 | 03 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,490 | $1,160 | Not Implemented |
CO0441 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,970 | $200 | Implemented |