IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

300

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0265 # 04 Y:2004 04 2004 BURN WASTE OIL FOR HEAT $3,362 $3,129 Not Implemented
MS0265 # 05 Y:2004 05 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,680 $189 Implemented
MS0265 # 06 Y:2004 06 2004 INSTALL TIMERS AND/OR THERMOSTATS $791 $472 Not Implemented
MS0265 # 07 Y:2004 07 2004 SHUT OFF PILOTS IN STANDBY EQUIPMENT $774 $176 Not Implemented
MS0264 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,471 $84,783 Implemented
MS0264 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,737 $318 Implemented
MS0264 # 03 Y:2004 03 2004 AIR CONDITION ONLY SPACE NECESSARY $2,457 $480 Not Implemented
MS0264 # 04 Y:2004 04 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,356 $1,624 Not Implemented
MS0264 # 05 Y:2004 05 2004 INSTALL TIMERS AND/OR THERMOSTATS $989 $944 Not Implemented
MS0264 # 06 Y:2004 06 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $183 $249 Not Implemented
MS0252 # 01 Y:2004 01 2004 USE RADIANT HEATER FOR SPOT HEATING $11,003 $10,413 Not Implemented
MS0252 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,867 $11,496 Implemented
MS0252 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,256 $230 Implemented
MS0252 # 04 Y:2004 04 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,835 $4,800 Not Implemented
MS0252 # 05 Y:2004 05 2004 RECOVER WASTE HEAT FROM EQUIPMENT $2,270 $1,731 Implemented
MS0252 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $535 $125 Implemented
MS0252 # 07 Y:2004 07 2004 INSTALL TIMERS AND/OR THERMOSTATS $207 $355 Not Implemented
MS0252 # 08 Y:2004 08 2004 INSTALL OCCUPANCY SENSORS $132 $346 Not Implemented
MS0236 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $23,086 $36,955 n/a
MS0236 # 02 Y:2003 02 2003 USE PHOTOCELL CONTROLS $2,939 $778 n/a
MS0236 # 03 Y:2003 03 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,626 $178 n/a
MS0236 # 04 Y:2003 04 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,290 $371 n/a
MS0235 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,844 $4,555 n/a
MS0235 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,701 $480 n/a
MS0235 # 03 Y:2003 03 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,654 $3,151 n/a