Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,208
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0143 # 03 Y:1989 | 03 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $252 | $75 | Implemented |
MA0143 # 04 Y:1989 | 04 | 1989 | REVISE SMOKE CLEANUP FROM OPERATIONS | $1,266 | $390 | Not Implemented |
MA0143 # 05 Y:1989 | 05 | 1989 | REVISE SMOKE CLEANUP FROM OPERATIONS | $4,545 | $980 | Implemented |
MA0143 # 06 Y:1989 | 06 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $2,142 | $3,000 | Implemented |
MA0143 # 07 Y:1989 | 07 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $19,116 | $25,000 | Not Implemented |
KU0275 # 01 Y:1989 | 01 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $582 | $1,068 | Implemented |
KU0275 # 02 Y:1989 | 02 | 1989 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,256 | $3,800 | Not Implemented |
KU0275 # 03 Y:1989 | 03 | 1989 | REDUCE VENTILATION AIR | $2,145 | $400 | Implemented |
KU0275 # 04 Y:1989 | 04 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,836 | $100 | Not Implemented |
KU0275 # 05 Y:1989 | 05 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,101 | $270 | Implemented |
KU0275 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,179 | $3,864 | Implemented |
KU0275 # 07 Y:1989 | 07 | 1989 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $204 | $0 | Implemented |
KU0275 # 08 Y:1989 | 08 | 1989 | IMPROVE LUBRICATION PRACTICES | $716 | $0 | Implemented |
KU0275 # 09 Y:1989 | 09 | 1989 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $349 | $358 | Implemented |
KU0275 # 10 Y:1989 | 10 | 1989 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $343 | $0 | Not Implemented |
KU0275 # 11 Y:1989 | 11 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $1,252 | $700 | Implemented |
UD0286 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,690 | $0 | Implemented |
UD0286 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,354 | $0 | Implemented |
UD0286 # 03 Y:1989 | 03 | 1989 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $543 | $0 | Implemented |
UD0286 # 04 Y:1989 | 04 | 1989 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $1,105 | $6,000 | Not Implemented |
UD0286 # 05 Y:1989 | 05 | 1989 | OPTIMIZE PLANT POWER FACTOR | $6,809 | $12,000 | Implemented |
UD0286 # 06 Y:1989 | 06 | 1989 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $117,912 | $60,000 | Implemented |
UD0286 # 07 Y:1989 | 07 | 1989 | INSTALL STORM WINDOWS AND DOORS | $47,948 | $47,000 | Not Implemented |
UD0286 # 08 Y:1989 | 08 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $9,312 | $0 | Implemented |
WI0051 # 01 Y:1989 | 01 | 1989 | IMPROVE LUBRICATION PRACTICES | $9,567 | $0 | Not Implemented |