Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,208
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CL2008 # 03 Y:2020 | 03 | 2020 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,758 | $2,616 | Implemented |
AM0805 # 01 Y:2020 | 01 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $28,160 | $575 | Implemented |
AM0805 # 02 Y:2020 | 02 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $23,400 | $3,000 | Implemented |
AM0805 # 03 Y:2020 | 03 | 2020 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $505 | $0 | Implemented |
AM0805 # 04 Y:2020 | 04 | 2020 | INSULATE BARE EQUIPMENT | $2,130 | $200 | Implemented |
AM0805 # 05 Y:2020 | 05 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,645 | $50 | Not Implemented |
AM0805 # 06 Y:2020 | 06 | 2020 | TURN OFF EQUIPMENT WHEN NOT IN USE | $140 | $15 | Implemented |
AM0805 # 07 Y:2020 | 07 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,150 | $370 | Implemented |
AM0805 # 08 Y:2020 | 08 | 2020 | USE SYNTHETIC LUBRICANT | $1,090 | $200 | Not Implemented |
AM0805 # 09 Y:2020 | 09 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,070 | $820 | Implemented |
AM0805 # 10 Y:2020 | 10 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,210 | $31,000 | Implemented |
AM0805 # 11 Y:2020 | 11 | 2020 | OPTIMIZE PLANT POWER FACTOR | $20,570 | $41,165 | Not Implemented |
AM0805 # 12 Y:2020 | 12 | 2020 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,920 | $7,400 | Not Implemented |
DL0182 # 01 Y:2020 | 01 | 2020 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,910 | $0 | Implemented |
DL0182 # 02 Y:2020 | 02 | 2020 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $33,900 | $25,200 | Implemented |
DL0182 # 03 Y:2020 | 03 | 2020 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $3,280 | $9,306 | Not Implemented |
DL0182 # 04 Y:2020 | 04 | 2020 | INSTALL TIMERS AND/OR THERMOSTATS | $4,920 | $60 | Not Implemented |
DL0182 # 05 Y:2020 | 05 | 2020 | REDUCE VENTILATION AIR | $290 | $0 | Not Implemented |
DL0182 # 06 Y:2020 | 06 | 2020 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,140 | $2,150 | Not Implemented |
DL0182 # 07 Y:2020 | 07 | 2020 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,320 | $1,000 | Not Implemented |
DL0182 # 08 Y:2020 | 08 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $349 | $1,440 | Not Implemented |
DL0182 # 09 Y:2020 | 09 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $800 | $879 | Implemented |
DL0182 # 10 Y:2020 | 10 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,845 | $1,900 | Not Implemented |
AM0802 # 01 Y:2020 | 01 | 2020 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $33,740 | $4,500 | Implemented |
AM0802 # 02 Y:2020 | 02 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,090 | $13,250 | Implemented |