Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
300
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0235 # 04 Y:2003 | 04 | 2003 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,634 | $50 | n/a |
MS0235 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,595 | $3,236 | n/a |
MS0235 # 06 Y:2003 | 06 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $1,207 | $500 | n/a |
MS0235 # 07 Y:2003 | 07 | 2003 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $485 | $568 | n/a |
MS0235 # 08 Y:2003 | 08 | 2003 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $424 | $64 | n/a |
MS0235 # 09 Y:2003 | 09 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $390 | $25 | n/a |
MS0235 # 10 Y:2003 | 10 | 2003 | USE PHOTOCELL CONTROLS | $172 | $38 | n/a |
MS0233 # 01 Y:2003 | 01 | 2003 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $200,928 | $9,650 | Implemented |
MS0233 # 02 Y:2003 | 02 | 2003 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $67,762 | $79,500 | Not Implemented |
MS0233 # 03 Y:2003 | 03 | 2003 | OPTIMIZE PLANT POWER FACTOR | $19,274 | $21,420 | Implemented |
MS0233 # 04 Y:2003 | 04 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,291 | $36,800 | Implemented |
MS0233 # 05 Y:2003 | 05 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $11,372 | $2,900 | Implemented |
MS0233 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,999 | $748 | Implemented |
MS0233 # 07 Y:2003 | 07 | 2003 | USE SYNTHETIC LUBRICANT | $3,787 | $1,210 | Implemented |
MS0233 # 08 Y:2003 | 08 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $1,622 | $1,535 | Not Implemented |
MS0233 # 09 Y:2003 | 09 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $579 | $968 | Implemented |
MS0225 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,764 | $670 | Implemented |
MS0225 # 02 Y:2003 | 02 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,290 | $4,667 | Implemented |
MS0225 # 03 Y:2003 | 03 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,074 | $1,368 | Not Implemented |
MS0225 # 04 Y:2003 | 04 | 2003 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $1,449 | $400 | Not Implemented |
MS0225 # 05 Y:2003 | 05 | 2003 | USE PHOTOCELL CONTROLS | $244 | $296 | Not Implemented |
MS0202 # 01 Y:2002 | 01 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,051 | $5,798 | Not Implemented |
MS0202 # 02 Y:2002 | 02 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,165 | $2,954 | Implemented |
MS0202 # 03 Y:2002 | 03 | 2002 | USE RADIANT HEATER FOR SPOT HEATING | $5,910 | $800 | Implemented |
MS0202 # 04 Y:2002 | 04 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $1,270 | $100 | Implemented |