Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
790
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0148 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,057 | $800 | n/a |
BD0148 # 08 Y:1999 | 08 | 1999 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $22,175 | $25,000 | n/a |
BD0148 # 10 Y:1999 | 10 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $49,668 | $0 | n/a |
BD0148 # 07 Y:1999 | 07 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $428 | $1,350 | n/a |
BD0148 # 06 Y:1999 | 06 | 1999 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $653 | $644 | n/a |
BD0148 # 05 Y:1999 | 05 | 1999 | INSTALL OCCUPANCY SENSORS | $945 | $1,350 | n/a |
BD0148 # 02 Y:1999 | 02 | 1999 | USE POWER DURING OFF-PEAK PERIODS | $9,788 | $1,000 | n/a |
BD0148 # 01 Y:1999 | 01 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,397 | $3,000 | n/a |
BD0148 # 09 Y:1999 | 09 | 1999 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $15,837 | $22,000 | n/a |
BD0148 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,112 | $0 | n/a |
ME0280 # 07 Y:1999 | 07 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,619 | $1,000 | Not Implemented |
ME0280 # 08 Y:1999 | 08 | 1999 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $1,092 | $1,240 | Implemented |
ME0280 # 01 Y:1999 | 01 | 1999 | INSTALL SENSORS TO DETECT DEFECTS | $243,000 | $20,108 | Implemented |
ME0280 # 06 Y:1999 | 06 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $3,402 | $4,940 | Implemented |
ME0280 # 02 Y:1999 | 02 | 1999 | MOVE PRODUCT USING MECHANICAL MEANS | $105,600 | $6,000 | Implemented |
ME0280 # 09 Y:1999 | 09 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $55,341 | $30,500 | Implemented |
ME0280 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,958 | $28,528 | Implemented |
ME0280 # 03 Y:1999 | 03 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $15,000 | $0 | Implemented |
ME0280 # 05 Y:1999 | 05 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,204 | $1,000 | Not Implemented |
BD0150 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $257 | $310 | Not Implemented |
BD0150 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,594 | $12,790 | Implemented |
BD0150 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $3,844 | $3,750 | Implemented |
BD0150 # 07 Y:1999 | 07 | 1999 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $26,208 | $5,000 | Implemented |
BD0150 # 09 Y:1999 | 09 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $426 | $0 | Implemented |
BD0150 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,905 | $1,000 | Implemented |