Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsSIC | 3411 | Metal Cans |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0679 # 05 Y:2003 | 05 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,465 | $200 | n/a |
UD0679 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,330 | $1,100 | n/a |
UD0679 # 03 Y:2003 | 03 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $12,046 | $270 | n/a |
UD0679 # 02 Y:2003 | 02 | 2003 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $52,385 | $1,125 | n/a |
UD0679 # 01 Y:2003 | 01 | 2003 | REDUCE VENTILATION AIR | $241,706 | $-3,800,000 | n/a |
UD0679 # 08 Y:2003 | 08 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,200 | $1,750 | n/a |
WV0235 # 05 Y:2002 | 05 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,013 | $444 | Not Implemented |
WV0235 # 09 Y:2002 | 09 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $14,000 | $6,000 | Not Implemented |
WV0235 # 08 Y:2002 | 08 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,968 | $2,500 | Not Implemented |
WV0235 # 07 Y:2002 | 07 | 2002 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,700 | $100 | Implemented |
WV0235 # 06 Y:2002 | 06 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,512 | $125 | Implemented |
WV0235 # 04 Y:2002 | 04 | 2002 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $9,017 | $750 | Implemented |
WV0235 # 03 Y:2002 | 03 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,006 | $3,100 | Implemented |
WV0235 # 02 Y:2002 | 02 | 2002 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,124 | $525 | Implemented |
WV0235 # 01 Y:2002 | 01 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $15,241 | $1,875 | Implemented |
UD0435 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,265 | $6,838 | Not Implemented |
UD0435 # 05 Y:1994 | 05 | 1994 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $28,851 | $50,000 | Not Implemented |
UD0435 # 03 Y:1994 | 03 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,090 | $5,000 | Not Implemented |
UD0435 # 02 Y:1994 | 02 | 1994 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,501 | $0 | Implemented |
UD0435 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $7,057 | $10,000 | Implemented |
UD0416 # 05 Y:1993 | 05 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,209 | $0 | Not Implemented |
UD0416 # 04 Y:1993 | 04 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $9,061 | $3,000 | Implemented |
UD0416 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,163 | $2,170 | Implemented |
UD0416 # 02 Y:1993 | 02 | 1993 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $17,440 | $20,000 | Not Implemented |
UD0416 # 01 Y:1993 | 01 | 1993 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,440 | $0 | Not Implemented |