Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 3429 | Hardware, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0187 # 09 Y:2000 | 09 | 2000 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $8,686 | $25,740 | Not Implemented |
NC0187 # 08 Y:2000 | 08 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $75 | $260 | Not Implemented |
NC0187 # 07 Y:2000 | 07 | 2000 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $3,506 | $5,416 | Not Implemented |
NC0187 # 06 Y:2000 | 06 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $17,072 | $24,000 | Not Implemented |
NC0187 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $689 | $1,428 | Not Implemented |
NC0187 # 04 Y:2000 | 04 | 2000 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $7,128 | $20,000 | Not Implemented |
NC0187 # 03 Y:2000 | 03 | 2000 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $975 | $2,640 | Not Implemented |
NC0187 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $10,033 | $5,000 | Not Implemented |
NC0187 # 01 Y:2000 | 01 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,836 | $1,000 | Not Implemented |
TN0639 # 06 Y:1998 | 06 | 1998 | USE OPTIMUM THICKNESS INSULATION | $470 | $1,125 | Not Implemented |
TN0639 # 05 Y:1998 | 05 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $754 | $950 | Implemented |
TN0639 # 04 Y:1998 | 04 | 1998 | RECOVER AND REUSE WASTE MATERIAL | $1,200 | $0 | Implemented |
TN0639 # 03 Y:1998 | 03 | 1998 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $4,680 | $0 | Implemented |
TN0639 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $5,440 | $3,440 | Implemented |
TN0639 # 01 Y:1998 | 01 | 1998 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $74,290 | $26,180 | Implemented |
NC0114 # 11 Y:1997 | 11 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $93,603 | $14,305 | Not Implemented |
NC0114 # 10 Y:1997 | 10 | 1997 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $4,888 | $10,500 | Implemented |
NC0114 # 09 Y:1997 | 09 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $3,150 | $1,096 | Implemented |
NC0114 # 08 Y:1997 | 08 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,459 | $5,200 | Implemented |
NC0114 # 07 Y:1997 | 07 | 1997 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $605 | $250 | Implemented |
NC0114 # 06 Y:1997 | 06 | 1997 | USE EVAPORATION TO CONCENTRATE MATERIAL | $9,198 | $12,000 | Not Implemented |
NC0114 # 05 Y:1997 | 05 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $110 | $56 | Not Implemented |
NC0114 # 04 Y:1997 | 04 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $179 | $400 | Implemented |
NC0114 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,248 | $510 | Implemented |
NC0114 # 02 Y:1997 | 02 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,857 | $2,925 | Implemented |