IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

51

matching recommendations
Reset
SIC 343 Plumbing And Heating, Except Electric
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0146 # 06 Y:1998 06 1998 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $2,431 $0 Implemented
NC0146 # 05 Y:1998 05 1998 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $13,890 $1,500 Implemented
NC0146 # 04 Y:1998 04 1998 RECOVER WASTE HEAT FROM EQUIPMENT $178 $200 Implemented
NC0146 # 03 Y:1998 03 1998 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $409 $1,480 Implemented
NC0146 # 02 Y:1998 02 1998 INSULATE BARE EQUIPMENT $920 $800 Implemented
NC0146 # 01 Y:1998 01 1998 COVER OPEN TANKS $488 $600 Implemented
SD0200 # 07 Y:1998 07 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,464 $14,319 Not Implemented
SD0200 # 01 Y:1998 01 1998 INSTALL TIMERS AND/OR THERMOSTATS $310 $340 Not Implemented
SD0200 # 02 Y:1998 02 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $809 $700 Implemented
SD0200 # 03 Y:1998 03 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,219 $2,364 Not Implemented
SD0200 # 04 Y:1998 04 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,197 $10,200 Implemented
SD0200 # 05 Y:1998 05 1998 INSTALL SPECTRAL REFLECTORS / DELAMP $2,402 $2,820 Not Implemented
SD0200 # 06 Y:1998 06 1998 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $13,838 $7,475 Not Implemented
SD0200 # 12 Y:1998 12 1998 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM $48,675 $50,000 Not Implemented
SD0200 # 09 Y:1998 09 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $480 $0 Implemented
SD0200 # 10 Y:1998 10 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $14,400 $0 Implemented
SD0200 # 08 Y:1998 08 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $4,320 $9,000 Implemented
SD0200 # 11 Y:1998 11 1998 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $6,318 $0 Implemented
SD0200 # 13 Y:1998 13 1998 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM $20,000 $0 Implemented
SD0200 # 14 Y:1998 14 1998 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $7,650 $18,840 Not Implemented
AR0137 # 08 Y:1998 08 1998 DISTILL CONTAMINATED SOLVENTS FOR REUSE $9,565 $4,500 Implemented
AR0137 # 06 Y:1998 06 1998 RECOVER AND REUSE COOLING WATER $4,245 $800 Implemented
AR0137 # 05 Y:1998 05 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,811 $215 Implemented
AR0137 # 03 Y:1998 03 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,133 $2,052 Implemented
AR0137 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,790 $628 Implemented