IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,546

matching recommendations
Reset
SIC 344 Fabricated Structural Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0475 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,280 $1,819 Implemented
OK0476 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,650 $90 Implemented
OK0476 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $900 $655 Implemented
OK0476 # 04 Y:1995 04 1995 INSTALL SET-BACK TIMERS $553 $200 Implemented
UF0127 # 01 Y:1995 01 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,065 $0 Implemented
UF0127 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $457 $935 Implemented
UF0127 # 03 Y:1995 03 1995 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $411 $500 Implemented
UF0127 # 04 Y:1995 04 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $784 $200 Implemented
KG0036 # 01 Y:1995 01 1995 USE POWER DURING OFF-PEAK PERIODS $12,130 $0 Implemented
KG0036 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,127 $500 Implemented
KG0036 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $790 $2,370 Implemented
KG0036 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $394 $459 Implemented
KG0036 # 06 Y:1995 06 1995 USE SYNTHETIC LUBRICANT $190 $0 Implemented
UM0034 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,759 $7,308 Implemented
UM0034 # 05 Y:1995 05 1995 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $2,450 $2,000 Implemented
MS0034 # 02 Y:1995 02 1995 DISCONNECT BALLASTS $1,005 $200 Implemented
MS0034 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $407 $321 Implemented
MS0034 # 04 Y:1995 04 1995 RECOVER WASTE HEAT FROM EQUIPMENT $3,696 $3,080 Implemented
MS0034 # 05 Y:1995 05 1995 INSTALL TIMERS AND/OR THERMOSTATS $818 $730 Implemented
MS0034 # 07 Y:1995 07 1995 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $629 $0 Implemented
AS0153 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,342 $4,568 Implemented
AS0153 # 02 Y:1995 02 1995 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,000 $0 Implemented
AS0153 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,551 $3,779 Implemented
AS0153 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $393 $0 Implemented
AS0153 # 07 Y:1995 07 1995 INSTALL TIMERS AND/OR THERMOSTATS $536 $1,000 Implemented