Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0225 # 09 Y:2003 | 09 | 2003 | USE SYNTHETIC LUBRICANT | $240 | $350 | Not Implemented |
BD0225 # 10 Y:2003 | 10 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $224 | $1,000 | Not Implemented |
BD0225 # 11 Y:2003 | 11 | 2003 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $7,920 | $2,200 | Not Implemented |
BD0225 # 12 Y:2003 | 12 | 2003 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $3,180 | $500 | Not Implemented |
BD0225 # 13 Y:2003 | 13 | 2003 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $400 | $120 | Not Implemented |
BD0225 # 14 Y:2003 | 14 | 2003 | USE POWER DURING OFF-PEAK PERIODS | $3,393 | $4,000 | Not Implemented |
BD0225 # 15 Y:2003 | 15 | 2003 | AUTOMATE PAYROLL SYSTEM | $2,080 | $2,500 | Not Implemented |
BD0225 # 16 Y:2003 | 16 | 2003 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $900 | $300 | Not Implemented |
SU0153 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $57,642 | $93,355 | Implemented |
SU0153 # 02 Y:2003 | 02 | 2003 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $42,094 | $93,819 | Not Implemented |
SU0153 # 03 Y:2003 | 03 | 2003 | INCREASE AMOUNT OF CONDENSATE RETURNED | $30,876 | $11,602 | Implemented |
SU0153 # 04 Y:2003 | 04 | 2003 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $12,993 | $7,176 | Not Implemented |
SU0153 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,229 | $438 | Implemented |
SU0153 # 06 Y:2003 | 06 | 2003 | OPTIMIZE PLANT POWER FACTOR | $5,043 | $16,501 | Implemented |
SU0153 # 07 Y:2003 | 07 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $4,900 | $16,700 | Implemented |
SU0153 # 08 Y:2003 | 08 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,098 | $12,105 | Not Implemented |
SU0153 # 09 Y:2003 | 09 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,467 | $163 | Implemented |
SU0153 # 10 Y:2003 | 10 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $882 | $249 | Not Implemented |
TA0043 # 01 Y:2002 | 01 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $12,980 | $0 | Implemented |
TA0043 # 02 Y:2002 | 02 | 2002 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,735 | $0 | Implemented |
TA0043 # 03 Y:2002 | 03 | 2002 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,390 | $0 | Implemented |
TA0043 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $670 | $0 | Implemented |
TA0043 # 05 Y:2002 | 05 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $140 | $75 | Not Implemented |
TA0043 # 06 Y:2002 | 06 | 2002 | INSTALL OCCUPANCY SENSORS | $101 | $163 | Not Implemented |
SD0306 # 01 Y:2002 | 01 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,205 | $23,000 | Not Implemented |