Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,493

matching recommendations
Reset
SIC 344 Fabricated Structural Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0076 # 09 Y:1997 09 1997 MINIMIZE WATER USAGE $304 $775 n/a
TN0599 # 01 Y:1997 01 1997 INSTALL EQUIPMENT TO MOVE PRODUCT $155,710 $69,000 Not Implemented
TN0599 # 02 Y:1997 02 1997 REVISE RAW MATERIAL SPECS $128,770 $0 Not Implemented
TN0599 # 03 Y:1997 03 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $92,330 $32,900 Not Implemented
TN0599 # 04 Y:1997 04 1997 REVISE RAW MATERIAL SPECS $50,700 $0 Not Implemented
TN0599 # 05 Y:1997 05 1997 INSTALL TIMERS AND/OR THERMOSTATS $19,720 $3,400 Not Implemented
TN0599 # 06 Y:1997 06 1997 INSTALL SKYLIGHTS $1,180 $1,000 Not Implemented
TN0599 # 07 Y:1997 07 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,110 $1,110 Not Implemented
HO0141 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,534 $16,787 Not Implemented
HO0141 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $798 $3,720 Not Implemented
HO0141 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,226 $400 Not Implemented
HO0141 # 04 Y:1997 04 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,306 $200 Not Implemented
HO0141 # 05 Y:1997 05 1997 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $2,232 $1,000 Implemented
HO0141 # 06 Y:1997 06 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $5,640 $0 Not Implemented
HO0141 # 07 Y:1997 07 1997 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $75,000 $40,000 Not Implemented
HO0141 # 08 Y:1997 08 1997 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $50,000 $50,000 Not Implemented
UD0507 # 01 Y:1996 01 1996 BURN A LESS EXPENSIVE GRADE OF FUEL $5,738 $7,500 Not Implemented
UD0507 # 02 Y:1996 02 1996 USE POWER DURING OFF-PEAK PERIODS $9,357 $0 Not Implemented
UD0507 # 03 Y:1996 03 1996 USE MINIMUM SAFE OVEN VENTILATION $1,228 $5,000 Implemented
UD0507 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $833 $3,271 Not Implemented
HO0138 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,476 $48,874 Implemented
HO0138 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $562 $1,215 Implemented
HO0138 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,943 $800 Implemented
HO0138 # 04 Y:1996 04 1996 CONVERT TO AIR ASSISTED / AIRLESS PAINT GUNS $1,500 $2,000 Not Implemented
OK0511 # 01 Y:1996 01 1996 USE RADIANT HEATER FOR SPOT HEATING $3,504 $18,090 Not Implemented