Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
384
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0082 # 05 Y:1994 | 05 | 1994 | CLOSE OFF UNNEEDED STEAM LINES | $3,376 | $2,500 | Not Implemented |
SD0082 # 06 Y:1994 | 06 | 1994 | INSULATE BARE EQUIPMENT | $1,613 | $655 | Implemented |
SD0082 # 07 Y:1994 | 07 | 1994 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,678 | $570 | Implemented |
SD0082 # 08 Y:1994 | 08 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,278 | $3,560 | Implemented |
SD0082 # 09 Y:1994 | 09 | 1994 | INSTALL SPECTRAL REFLECTORS / DELAMP | $5,162 | $5,175 | Not Implemented |
SD0082 # 10 Y:1994 | 10 | 1994 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $57 | $25 | Not Implemented |
SD0082 # 11 Y:1994 | 11 | 1994 | USE PHOTOCELL CONTROLS | $594 | $230 | Not Implemented |
SD0022 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,880 | $1,817 | Implemented |
SD0022 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,846 | $2,000 | Implemented |
SD0022 # 03 Y:1992 | 03 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $591 | $15 | Implemented |
SD0022 # 04 Y:1992 | 04 | 1992 | COVER OPEN TANKS | $516 | $169 | Implemented |
SD0022 # 05 Y:1992 | 05 | 1992 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $158 | $138 | Implemented |
SD0022 # 06 Y:1992 | 06 | 1992 | INSULATE BARE EQUIPMENT | $138 | $122 | Implemented |
SD0022 # 07 Y:1992 | 07 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $24,184 | $51,124 | Not Implemented |
SD0022 # 08 Y:1992 | 08 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $584 | $999 | Implemented |
SD0022 # 09 Y:1992 | 09 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,496 | $2,200 | Implemented |
SD0022 # 10 Y:1992 | 10 | 1992 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,222 | $0 | Implemented |
SD0006 # 01 Y:1991 | 01 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $490 | $605 | Not Implemented |
SD0006 # 02 Y:1991 | 02 | 1991 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $424 | $700 | Not Implemented |
SD0006 # 03 Y:1991 | 03 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,921 | $3,500 | Not Implemented |
SD0006 # 04 Y:1991 | 04 | 1991 | INSTALL SET-BACK TIMERS | $2,292 | $3,750 | Not Implemented |
SD0006 # 05 Y:1991 | 05 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $5,786 | $7,500 | Not Implemented |
SD0006 # 06 Y:1991 | 06 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $405 | $1,672 | Not Implemented |
SD0006 # 07 Y:1991 | 07 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16 | $21 | Not Implemented |
SD0006 # 08 Y:1991 | 08 | 1991 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $3,470 | $600 | Not Implemented |