Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

52

matching recommendations
Reset
SIC 344 Fabricated Structural Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0293 # 10 Y:2004 10 2004 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,815 $3,000 Not Implemented
WV0293 # 09 Y:2004 09 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,889 $210 Implemented
WV0293 # 08 Y:2004 08 2004 INSTALL OCCUPANCY SENSORS $1,935 $400 Not Implemented
WV0293 # 07 Y:2004 07 2004 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,353 $100 Not Implemented
WV0293 # 06 Y:2004 06 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,232 $4,250 Implemented
WV0293 # 04 Y:2004 04 2004 DEVELOP A REPAIR/REPLACE POLICY $3,874 $1,250 Implemented
WV0293 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,541 $13,500 Implemented
WV0293 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,117 $20,400 Implemented
WV0293 # 02 Y:2004 02 2004 REDESIGN PROCESS $12,155 $10,080 Not Implemented
OD0090 # 03 Y:1997 03 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $1,082 $0 Not Implemented
OD0090 # 02 Y:1997 02 1997 BURN A LESS EXPENSIVE GRADE OF FUEL $877 $688 Implemented
OD0090 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $863 $1,657 Not Implemented
OD0080 # 03 Y:1997 03 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $758 $320 Implemented
OD0080 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $85 $247 Not Implemented
OD0080 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,090 $150 Implemented
OD0080 # 04 Y:1997 04 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $65 $0 Implemented
OD0080 # 05 Y:1997 05 1997 INSTALL TIMERS AND/OR THERMOSTATS $563 $210 Implemented
OD0080 # 06 Y:1997 06 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $2,392 $0 Not Implemented
OD0070 # 03 Y:1996 03 1996 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $425 $100 Not Implemented
OD0070 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $850 $800 Implemented
OD0070 # 01 Y:1996 01 1996 USE SYNTHETIC LUBRICANT $648 $312 Not Implemented
OD0070 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,667 $1,436 Implemented
OD0070 # 06 Y:1996 06 1996 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $2,486 $800 Implemented
OD0070 # 05 Y:1996 05 1996 BURN WASTE OIL FOR HEAT $916 $2,585 Not Implemented
OD0024 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $652 $1,625 Implemented