Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
291
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0085 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $779 | $3,050 | Implemented |
WV0085 # 03 Y:1996 | 03 | 1996 | USE SYNTHETIC LUBRICANT | $250 | $400 | Implemented |
WV0085 # 04 Y:1996 | 04 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,694 | $500 | Implemented |
WV0085 # 05 Y:1996 | 05 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $9,180 | $9,200 | Not Implemented |
UD0466 # 01 Y:1995 | 01 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $627 | $1,000 | Not Implemented |
UD0466 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,867 | $3,000 | Not Implemented |
UD0466 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,108 | $1,530 | Not Implemented |
UD0466 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $816 | $960 | Not Implemented |
UD0466 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,117 | $640 | Not Implemented |
UD0443 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,736 | $16,000 | Implemented |
UD0443 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $595 | $1,280 | Implemented |
UD0443 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $4,063 | $10,000 | Implemented |
UD0443 # 04 Y:1994 | 04 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $416 | $2,000 | Implemented |
UD0388 # 01 Y:1992 | 01 | 1992 | ISOLATE HOT OR COLD EQUIPMENT | $7,341 | $0 | Implemented |
UD0388 # 02 Y:1992 | 02 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,088 | $3,000 | Not Implemented |
UD0388 # 03 Y:1992 | 03 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,341 | $800 | Implemented |
UD0387 # 01 Y:1992 | 01 | 1992 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $23,256 | $55,000 | Implemented |
UD0387 # 02 Y:1992 | 02 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $35,120 | $38,000 | Implemented |
UD0387 # 03 Y:1992 | 03 | 1992 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $4,668 | $0 | Implemented |
UD0387 # 04 Y:1992 | 04 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,850 | $1,000 | Implemented |
UD0387 # 05 Y:1992 | 05 | 1992 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,875 | $2,000 | Implemented |
UD0387 # 06 Y:1992 | 06 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $891 | $0 | Not Implemented |
UD0387 # 07 Y:1992 | 07 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,594 | $1,000 | Implemented |
UD0318 # 01 Y:1990 | 01 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $8,002 | $0 | Implemented |
UD0318 # 02 Y:1990 | 02 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,804 | $500 | Implemented |