IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,509

matching recommendations
Reset
SIC 344 Fabricated Structural Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UU0056 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $223 $136 Not Implemented
UU0056 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $190 $266 Not Implemented
UU0056 # 06 Y:2003 06 2003 RECOVER WASTE HEAT FROM EQUIPMENT $110 $490 Implemented
MS0236 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $23,086 $36,955 n/a
MS0236 # 02 Y:2003 02 2003 USE PHOTOCELL CONTROLS $2,939 $778 n/a
MS0236 # 03 Y:2003 03 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,626 $178 n/a
MS0236 # 04 Y:2003 04 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,290 $371 n/a
MS0235 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,844 $4,555 n/a
MS0235 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,701 $480 n/a
MS0235 # 03 Y:2003 03 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,654 $3,151 n/a
MS0235 # 04 Y:2003 04 2003 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,634 $50 n/a
MS0235 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,595 $3,236 n/a
MS0235 # 06 Y:2003 06 2003 INSTALL TIMERS AND/OR THERMOSTATS $1,207 $500 n/a
MS0235 # 07 Y:2003 07 2003 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $485 $568 n/a
MS0235 # 08 Y:2003 08 2003 SHUT OFF PILOTS IN STANDBY EQUIPMENT $424 $64 n/a
MS0235 # 09 Y:2003 09 2003 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $390 $25 n/a
MS0235 # 10 Y:2003 10 2003 USE PHOTOCELL CONTROLS $172 $38 n/a
NC0268 # 01 Y:2003 01 2003 AUTOMATE FINISHING PROCESS $29,974 $26,350 Not Implemented
NC0268 # 02 Y:2003 02 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $9,563 $8,000 Not Implemented
NC0268 # 03 Y:2003 03 2003 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $10,491 $2,000 Not Implemented
NC0268 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $693 $500 Implemented
NC0268 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $162 $329 Not Implemented
NC0268 # 06 Y:2003 06 2003 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $1,012 $300 Not Implemented
LL0175 # 01 Y:2003 01 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $9,977 $945 Not Implemented
LL0175 # 02 Y:2003 02 2003 USE PHOTOCELL CONTROLS $3,273 $280 Not Implemented