Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0322 # 03 Y:2003 | 03 | 2003 | INSTALL SKYLIGHTS | $4,917 | $6,000 | Not Implemented |
SD0322 # 04 Y:2003 | 04 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,952 | $0 | Implemented |
SD0322 # 05 Y:2003 | 05 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,614 | $2,250 | Not Implemented |
SD0322 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $579 | $350 | Not Implemented |
SD0322 # 07 Y:2003 | 07 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,321 | $240 | Implemented |
SD0322 # 08 Y:2003 | 08 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,814 | $5,000 | Not Implemented |
SD0322 # 09 Y:2003 | 09 | 2003 | CLEAR AND RENT EXISTING SPACE | $238,320 | $11,000 | Not Implemented |
SD0320 # 01 Y:2003 | 01 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $13,532 | $0 | Implemented |
SD0320 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,385 | $240 | Implemented |
SD0320 # 03 Y:2003 | 03 | 2003 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,863 | $1,670 | Not Implemented |
SD0320 # 04 Y:2003 | 04 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,957 | $1,185 | Implemented |
SD0320 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,692 | $2,961 | Implemented |
SD0320 # 06 Y:2003 | 06 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $1,621 | $500 | Implemented |
SD0320 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,327 | $1,412 | Implemented |
SD0320 # 08 Y:2003 | 08 | 2003 | USE PHOTOCELL CONTROLS | $1,032 | $2,000 | Not Implemented |
SD0320 # 09 Y:2003 | 09 | 2003 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $31,334 | $6,000 | Implemented |
SD0320 # 10 Y:2003 | 10 | 2003 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $9,120 | $0 | Not Implemented |
BD0225 # 01 Y:2003 | 01 | 2003 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $3,792 | $10,000 | Not Implemented |
BD0225 # 02 Y:2003 | 02 | 2003 | INSTALL OCCUPANCY SENSORS | $1,196 | $2,100 | Not Implemented |
BD0225 # 03 Y:2003 | 03 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,618 | $5,072 | Not Implemented |
BD0225 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $724 | $3,630 | Not Implemented |
BD0225 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $873 | $300 | Not Implemented |
BD0225 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $439 | $2,280 | Not Implemented |
BD0225 # 07 Y:2003 | 07 | 2003 | DISCONNECT BALLASTS | $442 | $60 | Not Implemented |
BD0225 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $338 | $270 | Not Implemented |