Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
128
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0827 # 02 Y:2010 | 02 | 2010 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $5,123 | $58,000 | Not Implemented |
UD0827 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $207 | $585 | Not Implemented |
UD0827 # 06 Y:2010 | 06 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $15,685 | $48,000 | Not Implemented |
UD0827 # 07 Y:2010 | 07 | 2010 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $597 | $50 | Implemented |
UD0827 # 03 Y:2010 | 03 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,804 | $5,800 | Not Implemented |
UD0827 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $995 | $500 | Implemented |
UD0827 # 04 Y:2010 | 04 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,258 | $800 | Not Implemented |
AM0586 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $30,790 | $3,000 | Implemented |
AM0586 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $42,330 | $42,750 | Not Implemented |
AM0586 # 03 Y:2010 | 03 | 2010 | MODIFY WORKLOAD | $19,890 | $0 | Not Implemented |
AM0586 # 08 Y:2010 | 08 | 2010 | USE PHOTOCELL CONTROLS | $1,345 | $200 | Not Implemented |
AM0586 # 04 Y:2010 | 04 | 2010 | OPTIMIZE PLANT POWER FACTOR | $13,800 | $53,380 | Not Implemented |
AM0586 # 05 Y:2010 | 05 | 2010 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $13,725 | $0 | Implemented |
AM0586 # 07 Y:2010 | 07 | 2010 | USE SYNTHETIC LUBRICANT | $2,195 | $0 | Not Implemented |
AM0586 # 06 Y:2010 | 06 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,660 | $2,040 | Not Implemented |
MI0197 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,774 | $1,210 | Implemented |
MI0197 # 05 Y:2010 | 05 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,359 | $2,850 | Not Implemented |
MI0197 # 01 Y:2010 | 01 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $23,798 | $2,550 | Not Implemented |
MI0197 # 07 Y:2010 | 07 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,983 | $2,040 | Implemented |
MI0197 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,824 | $7,562 | Not Implemented |
MI0197 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,187 | $180 | Implemented |
MI0197 # 03 Y:2010 | 03 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,594 | $40 | Not Implemented |
WV0413 # 02 Y:2010 | 02 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $89,967 | $129,542 | Not Implemented |
WV0413 # 01 Y:2010 | 01 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $108,743 | $89,900 | Not Implemented |
WV0413 # 16 Y:2010 | 16 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $288 | $357 | Implemented |