Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
33
matching recommendationsSIC | 3441 | Fabricated Structural Metal |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0891 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $641 | $300 | Not Implemented |
UD0891 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,992 | $27,380 | Not Implemented |
UD0891 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $868 | $1,000 | Implemented |
UD0891 # 03 Y:2013 | 03 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,643 | $30,000 | Not Implemented |
UD0891 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,664 | $3,000 | Implemented |
UD0891 # 01 Y:2013 | 01 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $112,427 | $100,000 | Not Implemented |
UM0195 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $262 | $1,052 | Not Implemented |
UM0195 # 01 Y:2001 | 01 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,400 | $3,150 | Not Implemented |
UM0195 # 02 Y:2001 | 02 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $329 | $500 | Implemented |
UM0195 # 03 Y:2001 | 03 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $755 | $1,000 | Not Implemented |
UM0195 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,182 | $375 | Implemented |
UM0195 # 05 Y:2001 | 05 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $551 | $500 | Not Implemented |
UM0117 # 07 Y:1998 | 07 | 1998 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $11,000 | $11,000 | Not Implemented |
UM0117 # 06 Y:1998 | 06 | 1998 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $2,059 | $250 | Implemented |
UM0117 # 05 Y:1998 | 05 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $14,400 | $1,000 | Not Implemented |
UM0117 # 04 Y:1998 | 04 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,314 | $658 | Implemented |
UM0117 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $724 | $1,000 | Implemented |
UM0117 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,896 | $9,124 | Implemented |
UM0117 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $558 | $918 | Implemented |
ND0290 # 02 Y:1997 | 02 | 1997 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $698 | $600 | Not Implemented |
ND0290 # 09 Y:1997 | 09 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $20 | $0 | Implemented |
ND0290 # 08 Y:1997 | 08 | 1997 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $303 | $335 | Implemented |
ND0290 # 07 Y:1997 | 07 | 1997 | PAY BILLS ON TIME TO AVOID LATE FEES | $325 | $0 | Implemented |
ND0290 # 06 Y:1997 | 06 | 1997 | INSTALL REPLACEMENT DOORS | $355 | $1,050 | Implemented |
ND0290 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $452 | $400 | Not Implemented |