Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,112

matching recommendations
Reset
SIC 3441 Fabricated Structural Metal
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0195 # 07 Y:2004 07 2004 INSTALL OCCUPANCY SENSORS $225 $240 Implemented
LL0195 # 08 Y:2004 08 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,500 $60 Implemented
LL0195 # 09 Y:2004 09 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $412 $226 Implemented
LE0187 # 01 Y:2004 01 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $18,829 $10,000 Not Implemented
LE0187 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,995 $500 Implemented
LE0187 # 03 Y:2004 03 2004 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $5,383 $9,360 Not Implemented
LE0187 # 04 Y:2004 04 2004 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $4,271 $40,064 Not Implemented
LE0187 # 05 Y:2004 05 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,975 $15,000 Not Implemented
LE0187 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $921 $500 Implemented
LE0187 # 07 Y:2004 07 2004 USE SYNTHETIC LUBRICANT $810 $500 Not Implemented
LL0189 # 01 Y:2004 01 2004 OPTIMIZE PLANT POWER FACTOR $16,554 $30,485 Implemented
LL0189 # 02 Y:2004 02 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $14,949 $8,940 Implemented
LL0189 # 03 Y:2004 03 2004 USE PHOTOCELL CONTROLS $11,938 $330 Not Implemented
LL0189 # 04 Y:2004 04 2004 USE RADIANT HEATER FOR SPOT HEATING $10,711 $15,908 Not Implemented
LL0189 # 05 Y:2004 05 2004 INSTALL TIMERS AND/OR THERMOSTATS $8,568 $1,430 Not Implemented
LL0189 # 06 Y:2004 06 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,506 $42,903 Implemented
LL0189 # 07 Y:2004 07 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $387 $305 Not Implemented
LL0189 # 08 Y:2004 08 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,500 $60 Implemented
LL0189 # 09 Y:2004 09 2004 COMBINE UTILITY METERS $338 $60 Implemented
WV0293 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,117 $20,400 Implemented
WV0293 # 02 Y:2004 02 2004 REDESIGN PROCESS $12,155 $10,080 Not Implemented
WV0293 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,541 $13,500 Implemented
WV0293 # 04 Y:2004 04 2004 DEVELOP A REPAIR/REPLACE POLICY $3,874 $1,250 Implemented
WV0293 # 05 Y:2004 05 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,283 $300 Not Implemented
WV0293 # 06 Y:2004 06 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,232 $4,250 Implemented